UNLABELLED: A 47-year-old male patient was admitted to our hospital with acute anterior myocardial infarction. Immediate coronary angiography was carried out, which showed proximal occlusion of the left anterior descending artery (LAD). After mechanical recanalization, a reduction in vessel caliber at the site of occlusion was visible, and balloon angioplasty with consecutive stent implantation because of vessel wall dissection was performed. After the procedure, diameter reduction of the entire vessel segment distal to the stent and muscular bridging with subtotal systolic obliteration of the LAD and one diagonal branch were demonstrated. Diastolic coronary flow did not appear to be limited (TIMI 3). Dipyridamole-thallium cardiac imaging revealed an incomplete perfusion defect of the anteroseptal region and a reversible perfusion reduction of the anterolateral region. For definitive treatment, we decided to implant a 3.0 mm-stent at the site of muscular bridging. Although balloon sizing was adapted to the diameter of the proximal reference segment, measured by quantitative coronary angiography, coronary perforation into the right ventricular outflow tract due to balloon oversizing in the distal dilation segment occurred. The patient remained asymptomatic at rest as well as under exercise testing, and hemodynamics remained stable. Coronary re-angiography after 1 week demonstrated a persistent fistula with complete opacification of the LAD and normal coronary flow (TIMI 3). Within the following 3 months, the coronary fistula closed spontaneously.

CONCLUSIONS: Muscular bridging is a rare cause of acute myocardial infarction. Balloon angioplasty and stent implantation in the bridged segment may be complicated by coronary artery perforation due to balloon oversizing. Risks and benefits of this therapeutic option, therefore, have to be critically evaluated, and careful selection of balloon size using measurements of proximal and distal reference diameter assessed by intravascular ultrasound is recommended. Coronary artery perforation into the myocardium with subsequent development of a fistula may be treated conservatively as long as the patient remains asymptomatic. The frequency of spontaneous closure of the fistula is high.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app