Comparison of the Bullard and Macintosh laryngoscopes for endotracheal intubation of patients with a potential cervical spine injury.

Anesthesiology 1997 December
BACKGROUND: In the emergency trauma situation, in-line stabilization (ILS) of the cervical spine is used to reduce head and neck extension during laryngoscopy. The Bullard laryngoscope may result in less cervical spine movement than the Macintosh laryngoscope. The aim of this study was to compare cervical spine extension (measured radiographically) and time to intubation with the Bullard and Macintosh laryngoscopes during a simulated emergency with cervical spine precautions taken.

METHODS: Twenty-nine patients requiring general anesthesia and endotracheal intubation were studied. Patients were placed on a rigid board and anesthesia was induced. Laryngoscopy was performed on four occasions: with the Bullard and Macintosh laryngoscopes both with and without manual ILS. Cricoid pressure was applied with ILS. To determine cervical spine extension, radiographs were exposed before and during laryngoscopy. Times to intubation and grade view of the larynx were also compared.

RESULTS: Cervical spine extension (occiput-C5) was greatest with the Macintosh laryngoscope (25.9 degrees +/- 2.8 degrees). Extension was reduced when using the Macintosh laryngoscope with ILS (12.9 +/- 2.1 degrees) and the Bullard laryngoscope without stabilization (12.6 +/- 1.8 degrees; P < 0.05). Times to intubation were similar for the Macintosh laryngoscope with ILS (20.3 +/- 12.8 s) and for the Bullard without ILS (25.6 +/- 10.4 s). Manual ILS with the Bullard laryngoscope results in further reduction in cervical spine extension (5.6 +/- 1.5 degrees) but prolongs time to intubation (40.3 +/- 19.5 s; P < 0.05).

CONCLUSIONS: Cervical spine extension and time to intubation are similar for the Macintosh laryngoscope with ILS and the Bullard laryngoscope without ILS. However, time to intubation is significantly prolonged when the Bullard laryngoscope is used in a simulated emergency with cervical spine precautions taken. This suggests that the Bullard laryngoscope may be a useful adjunct to intubation of patients with potential cervical spine injury when time to intubation is not critical.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app