Journal of Computer Assisted Tomography 1997 September
PURPOSE: The goal of this study was to evaluate a newly developed semiautomated contour detection algorithm for the quantitative analysis of cardiovascular MRI.
METHOD: Left ventricular function parameters derived from automatically detected endocardial and epicardial contours were compared with results derived from manually traced contours in short-axis multislice GRE MRI studies of 10 normal volunteers and 10 infarct patients.
RESULTS: Compared with manual image analysis, the semiautomated method resulted in the following systematic and random differences (auto-manual; mean +/- SD): end-diastolic volume: -5.5 +/- 9.7 ml; end-systolic volume: -3.6 +/- 6.5 ml; ejection fraction: 1.7 +/- 4.1%; left ventricular mass: 7.3 +/- 20.6 g. Total analysis time for a complete study was reduced from 3-4 h for the manual analysis to < 20 min using semiautomated contour detection.
CONCLUSION: Global left ventricular function parameters can be obtained with a high degree of accuracy and precision using the present semiautomated contour detection algorithm.
METHOD: Left ventricular function parameters derived from automatically detected endocardial and epicardial contours were compared with results derived from manually traced contours in short-axis multislice GRE MRI studies of 10 normal volunteers and 10 infarct patients.
RESULTS: Compared with manual image analysis, the semiautomated method resulted in the following systematic and random differences (auto-manual; mean +/- SD): end-diastolic volume: -5.5 +/- 9.7 ml; end-systolic volume: -3.6 +/- 6.5 ml; ejection fraction: 1.7 +/- 4.1%; left ventricular mass: 7.3 +/- 20.6 g. Total analysis time for a complete study was reduced from 3-4 h for the manual analysis to < 20 min using semiautomated contour detection.
CONCLUSION: Global left ventricular function parameters can be obtained with a high degree of accuracy and precision using the present semiautomated contour detection algorithm.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Essential thrombocythaemia: A contemporary approach with new drugs on the horizon.British Journal of Haematology 2024 April 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app