PURPOSE: The Summit Therapeutic Refractive Clinical Trial is a nine-center prospective, nonrandomized, self-controlled trial to assess the efficacy, stability, and safety of using a standardized technique of excimer laser photorefractive keratectomy (PRK) to correct residual myopia in eyes with previous refractive surgery or cataract surgery.
PATIENTS AND METHODS: Eligible eyes with a mean residual myopia of -3.7 +/- 1.8 diopters (D) (range, -0.63 to -11.00 D) underwent PRK with a 193-nm excimer laser for myopic corrections between -1.50 and -7.50 D. Standardized settings were used for the ablation zone, ablation rate, repetition rate, and fluence. One hundred seven of the first 114 treated eyes were examined 1 year after PRK, with 98% of eyes having had refractive keratotomy and 2% having had cataract surgery.
RESULTS: One year postoperatively, the mean manifest spherical equivalent refraction was -0.6 +/- 1.4 D (range, -6.50 to 2.50 D); 63% of eyes were within +/-1.00 D of the attempted correction; and uncorrected visual acuity was 20/40 or better in 74% of eyes. Twenty-nine percent of eyes lost two or more Snellen lines of best-corrected visual acuity, and central corneal haze was moderate or severe in 8% of eyes.
CONCLUSIONS: Excimer laser PRK is effective in reducing residual myopia after previous refractive and cataract surgery. However, it is less accurate than PRK in eyes that did not undergo surgery and is more likely to cause a loss of best-corrected visual acuity 1 year after treatment.
PATIENTS AND METHODS: Eligible eyes with a mean residual myopia of -3.7 +/- 1.8 diopters (D) (range, -0.63 to -11.00 D) underwent PRK with a 193-nm excimer laser for myopic corrections between -1.50 and -7.50 D. Standardized settings were used for the ablation zone, ablation rate, repetition rate, and fluence. One hundred seven of the first 114 treated eyes were examined 1 year after PRK, with 98% of eyes having had refractive keratotomy and 2% having had cataract surgery.
RESULTS: One year postoperatively, the mean manifest spherical equivalent refraction was -0.6 +/- 1.4 D (range, -6.50 to 2.50 D); 63% of eyes were within +/-1.00 D of the attempted correction; and uncorrected visual acuity was 20/40 or better in 74% of eyes. Twenty-nine percent of eyes lost two or more Snellen lines of best-corrected visual acuity, and central corneal haze was moderate or severe in 8% of eyes.
CONCLUSIONS: Excimer laser PRK is effective in reducing residual myopia after previous refractive and cataract surgery. However, it is less accurate than PRK in eyes that did not undergo surgery and is more likely to cause a loss of best-corrected visual acuity 1 year after treatment.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app