Diagnostic and therapeutic implications of transesophageal echocardiography in medical ICU patients with unexplained shock, hypoxemia, or suspected endocarditis.

OBJECTIVE: To evaluate the diagnostic and therapeutic implications of transesophageal echocardiography (TEE) in intensive care patients.

DESIGN: Comparative study.

SETTING: A 10-bed general intensive care unit.

PATIENTS: Between 1 January 1992 and 31 May 1993, 61 patients prospectively identified with shock (n = 14), severe, unexplained hypoxemia (Partial pressure of oxygen in arterial blood/fractional inspired oxygen < 200) (n = 31), or suspected endocarditis (n = 16) underwent a TEE examination to supplement transthoracic echocardiography (TTE) examination.

INTERVENTIONS: The results of each TEE examination were compared with the clinical findings and TTE data. TEE examinations were classified as follows: 0, TEE results were similar to TTE results; 00, TEE examination resulted in exclusion of suspected abnormalities; 1, TEE revealed a new but minor diagnosis compared to the TTE diagnosis; 2, TEE revealed a new major diagnosis not requiring a change of treatment; 3, TEE results revealed a new major diagnosis requiring an immediate change of treatment.

RESULTS: Intraobserver reliability of the TEE classification was confirmed by a 100% concordance and interobserver reliability was evaluated as an 84% concordance. Results of the TEE classification were: class 0, n = 21 (34%); class 00, n = 13 (21%); class 1, n = 7 (12%); class 2, n = 8 (13%); class 3, n = 12 (20%). Therapeutic implications of TEE in class 3 patients were cardiac surgery in 5 patients (2 cases of acute mitral regurgitation, 2 valvular abscesses, and 1 hematoma compressing the left atrium), discontinuation of positive end-expiratory pressure in 1 ventilated patient with an atrial septal defect, weaning off mechanical ventilation in 1 patient with an atrial septal defect, prescription of antimicrobial therapy in 3 patients with endocarditis, and prescription of anticoagulant therapy in 2 patients with left atrial thrombus. No difficulty inserting the transducer was observed in any of the 61 patients studied. The only noteworthy complication was a case of spontaneously resolving atrial fibrillation.

CONCLUSION: TEE is safe and well tolerated and is useful in the management of patients in the intensive care unit with shock, unexplained and severe hypoxemia, or suspected endocarditis when TTE is inconclusive.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app