Add like
Add dislike
Add to saved papers

[Hydrospiral CT of the pancreas in thin section technique].

Der Radiologe 1996 May
PURPOSE: To evaluate a new technique for imaging the pancreas (spiral hydro-CT) based on a combination of pharmacological intestinal paralysis and water distension of the stomach and duodenum with specific reference to tumor detection rate, differentiation of malignant versus benign tumors, differential diagnosis and assessment of tumor resectability.

MATERIAL AND METHODS: In an open prospective study, 151 patients with a suspected pancreatic neoplasm based on clinical, laboratory or other imaging data were examined between May 94 and October 95. Our newly developed Hydro-CT methodology included intravenous injection of 40 mg N-butylscopolaminium bromide (Buscopan) for intestinal paralysis, gastric and duodenal wall distension by oral administration of an average of 1.51 warm tap water, 30 degrees RAO patient positioning, an individualized contrast injection technique as determined beforehand by time-to-peak measurement in the portal vein and thin-slice spiral CT (3 mm increment, 6 mm table feed and 3 mm secondary reconstruction). A detailed evaluation form was used to assess (1) tumor detection rate, (2) differentiation of malignant versus benign disease, (3) differential diagnosis, and (4) accuracy of assessment of resectability by identification of infiltration into adjacent organs and vessel structures relevant for resectability such as splenic, superior mesenteric, portal vein and celiac trunk, superior mesenteric, splenic and hepatic arteries. As the gold standard for positive tumor detection surgery and microscopic diagnosis were used, and for negative tumor detection an event-free survival of 6 months.

RESULTS: Almost all examinations were well tolerated. In only 4% was on-site administration of a gastric tube required because of vomiting. In 2% of the patients a slight allergic reaction to the contrast medium was seen. The prevalence of a pancreatic neoplasm was 38%. In tumor detection Hydro-CT reached an overall accuracy of 97.4% with a sensitivity of 100% and a specificity of 95.9%. In the differentiation of benign versus malignant disease Hydro-CT reached an overall accuracy of 89.7% with a sensitivity of 92.5% and a specificity of 83.3%. The prevalence of a pancreatic carcinoma was 24%; 4% other malignant tumors were found (distal common bile duct carcinoma, cystadenocarcinoma). Fifty-eight patients underwent surgical exploration. In those assessment of resectability reached an overall accuracy of 95% with a sensitivity of 90.5% and specificity of 100%.

CONCLUSION: The new technique of Hydro-CT based on thin slice and spiral methodology, including pharmacological intestinal paralysis and water distension, results in a high tumor detection rate and increases sensitivity and specificity of tumor differential diagnosis and of assessment of resectability.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

Managing Alcohol Withdrawal Syndrome.Annals of Emergency Medicine 2024 March 26

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app