Detection of deep venous thrombosis by magnetic resonance imaging.
Chest 1993 July
OBJECTIVE: To determine the accuracy of gradient recalled echo magnetic resonance imaging in assessing deep venous thrombosis.
DESIGN: This is a retrospective review of a prospective clinical experience in 216 consecutive patients studied using gradient recalled echo magnetic resonance imaging. Sixteen patients were unavailable for follow-up and 1 study was technically suboptimal, leaving 199 studies as the basis of this report.
RESULTS: In 79 cases with confirmatory venography (n = 54), ultrasound (n = 16, thigh veins only), or computed tomography (n = 9, pelvic veins only), magnetic resonance imaging was 97 percent sensitive, 95 percent specific, and 96 percent accurate. Including cases that were normal by magnetic resonance imaging, not anticoagulated, and with uneventful follow-up as true normal cases, the corresponding sensitivity, specificity, and accuracy of magnetic resonance imaging were as follows: 97 percent, 98 percent, and 97 percent.
CONCLUSION: Magnetic resonance imaging, using gradient recalled echo acquisitions, is capable of accurately diagnosing acute deep venous thrombosis.
DESIGN: This is a retrospective review of a prospective clinical experience in 216 consecutive patients studied using gradient recalled echo magnetic resonance imaging. Sixteen patients were unavailable for follow-up and 1 study was technically suboptimal, leaving 199 studies as the basis of this report.
RESULTS: In 79 cases with confirmatory venography (n = 54), ultrasound (n = 16, thigh veins only), or computed tomography (n = 9, pelvic veins only), magnetic resonance imaging was 97 percent sensitive, 95 percent specific, and 96 percent accurate. Including cases that were normal by magnetic resonance imaging, not anticoagulated, and with uneventful follow-up as true normal cases, the corresponding sensitivity, specificity, and accuracy of magnetic resonance imaging were as follows: 97 percent, 98 percent, and 97 percent.
CONCLUSION: Magnetic resonance imaging, using gradient recalled echo acquisitions, is capable of accurately diagnosing acute deep venous thrombosis.
Full text links
Trending Papers
Restrictive fluid resuscitation in septic shock patients has lower mortality and organ dysfunction rates than standard therapy.Shock 2023 November 11
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app