CLINICAL TRIAL
JOURNAL ARTICLE
RANDOMIZED CONTROLLED TRIAL
Add like
Add dislike
Add to saved papers

Sustained cardiac diastolic changes elicited by ultrafiltration in patients with moderate congestive heart failure: pathophysiological correlates.

OBJECTIVE: To investigate the pathophysiological (cardiac function and physical performance) significance of clinically silent interstitial lung water accumulation in patients with moderate heart failure; to use isolated ultrafiltration as a means of extravascular fluid reabsorption.

DESIGN: Echocardiographic, Doppler, chest x-ray evaluations, and cardiopulmonary tests at baseline, soon after ultrafiltration (veno venous extracorporeal circuit), and four days, one month, and three months later.

SETTING: University institute of cardiology.

SUBJECTS: 24 patients with heart failure due to idiopathic dilated cardiomyopathy or ischaemic myocardial disease with sinus rhythm and ejection fraction less than 35%. Twelve were randomised to ultrafiltration and 12 were taken as controls.

MAIN OUTCOME MEASURES: Left ventricular systolic function (from ultrasonography); Doppler evaluation of mitral, tricuspid, and aortic flow and echo-Doppler determination of cardiac output; radiological score of extravascular lung water; right and left ventricular filling pressures; oxygen consumption at peak exercise and exercise tolerance time in cardiopulmonary tests.

RESULTS: Soon after ultrafiltration (1976 (760) ml of fluid removed) the following was observed: a reduction in radiological score of extravascular lung water (from 15(1) to 9(1)) and of right (from 7.1 (2.3) to 2.3 (1.7) mm Hg) and left (from 17.6 (8.8) to 9.5 (6.4) mm Hg) ventricular filling pressures; an increase in oxygen consumption at peak exercise (from 15.8 (3.3) to 17.6 (2) ml/min/kg) and of tolerance time (from 444 (138) to 508 (134) s); a slight decrease in atrial and ventricular dimensions; no changes in the systolic function of the left ventricle; a reduction of the early to late filling ratio in both ventricles (mitral valve from 2 (2) to 1.1 (1.1)); (tricuspid valve from 1.3 (1.3) to 0.69 (0.18)) and an increase in the deceleration time of mitral and tricuspid flow, reflecting a redistribution of filling to late diastole. Variations in the ventricular filling pattern, lung water content, and functional performance persisted for three months in all cases. None of these changes was detected in the control group.

CONCLUSIONS: Reduction of interstitial lung water was probably the mechanism whereby ultrafiltration modified the pattern of filling of the two ventricles and improved functional performance.

Full text links

For the best experience, use the Read mobile app

Group 7SearchHeart failure treatmentPapersTopicsCollectionsEffects of Sodium-Glucose Cotransporter 2 Inhibitors for the Treatment of Patients With Heart Failure Importance: Only 1 class of glucose-lowering agents-sodium-glucose cotransporter 2 (SGLT2) inhibitors-has been reported to decrease the risk of cardiovascular events primarily by reducingSeptember 1, 2017: JAMA CardiologyAssociations of albuminuria in patients with chronic heart failure: findings in the ALiskiren Observation of heart Failure Treatment study.CONCLUSIONS: Increased UACR is common in patients with heart failure, including non-diabetics. Urinary albumin creatininineJul, 2011: European Journal of Heart FailureRandomized Controlled TrialEffects of Liraglutide on Clinical Stability Among Patients With Advanced Heart Failure and Reduced Ejection Fraction: A Randomized Clinical Trial.Review

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app