CLINICAL TRIAL
JOURNAL ARTICLE
RANDOMIZED CONTROLLED TRIAL
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Complications and failures of subclavian-vein catheterization.

BACKGROUND: Although catheterization of the subclavian vein is a common procedure, the risk factors for complications and failures, with the exception of the physician's experience, are poorly understood. Ultrasonography has been recommended to help guide the placement of central venous catheters.

METHODS: We conducted a prospective randomized trial of ultrasound-guided location of the subclavian vein as compared with standard insertion procedures. In the group of patients undergoing catheterization with ultrasound guidance, the site of the insertion was marked before the catheterization attempt; real-time ultrasound guidance was not used. The 821 eligible patients (411 in the ultrasound group and 410 in the control group) underwent catheterization in a single procedure suite under controlled nonemergency conditions, in most cases for the administration of chemotherapy.

RESULTS: Ultrasound guidance had no effect on the rate of complications or failures of subclavian-vein catheterization (risk ratio for complications, 1.00; 95 percent confidence interval, 0.66 to 1.52; risk ratio for failures, 1.04; 95 percent confidence interval, 0.72 to 1.50). In multivariate analyses, prior major surgery in the region (P = 0.002), a body-mass index (the weight in kilograms divided by the square of the height in meters) higher than 30 or lower than 20 (P = 0.009), and previous catheterization (P = 0.043) were associated with failed attempts. Complications were also associated with failed attempts: 52 of the 721 patients (7.2 percent) in whom catheterization was successful had complications, as compared with 28 of the 100 patients (28 percent) in whom physicians were unable to place catheters. The number of needle passes was strongly associated with the rates of failure and complications. The complication rate rose from 4.3 percent with one pass to 24.0 percent with more than two passes.

CONCLUSIONS: Ultrasound guidance of subclavian-vein catheterization, as used in this study, was not beneficial. In patients at highest risk for complications and failures, catheterization should be attempted by the most experienced physicians available.

Full text links

For the best experience, use the Read mobile app

Group 7SearchHeart failure treatmentPapersTopicsCollectionsEffects of Sodium-Glucose Cotransporter 2 Inhibitors for the Treatment of Patients With Heart Failure Importance: Only 1 class of glucose-lowering agents-sodium-glucose cotransporter 2 (SGLT2) inhibitors-has been reported to decrease the risk of cardiovascular events primarily by reducingSeptember 1, 2017: JAMA CardiologyAssociations of albuminuria in patients with chronic heart failure: findings in the ALiskiren Observation of heart Failure Treatment study.CONCLUSIONS: Increased UACR is common in patients with heart failure, including non-diabetics. Urinary albumin creatininineJul, 2011: European Journal of Heart FailureRandomized Controlled TrialEffects of Liraglutide on Clinical Stability Among Patients With Advanced Heart Failure and Reduced Ejection Fraction: A Randomized Clinical Trial.Review

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app