We have located links that may give you full text access.
CLINICAL TRIAL
COMPARATIVE STUDY
JOURNAL ARTICLE
MULTICENTER STUDY
RANDOMIZED CONTROLLED TRIAL
RESEARCH SUPPORT, U.S. GOV'T, NON-P.H.S.
Variability in measurement of abdominal aortic aneurysms. Abdominal Aortic Aneurysm Detection and Management Veterans Administration Cooperative Study Group.
Journal of Vascular Surgery 1995 June
PURPOSE: The purpose of this study was to report interobserver and intraobserver variability of computed tomography (CT) measurements of abdominal aortic aneurysm (AAA) diameter and agreement between CT and ultrasonography observed in the course of a large, multicenter, randomized trial on the management of small AAAs.
METHODS: CT measurements of AAA diameter from participating centers were compared with measurements made from the same scan by a central laboratory. Blinded central remeasurement of a randomly selected subset of these CT scans was used to assess intraobserver variability. Agreement between AAA measurements by CT and ultrasonography done within 30 days of each other was also assessed.
RESULTS: For interobserver pairs of local and central CT measurements of AAA diameter (n = 806), the difference was 0.2 cm or less in 65% of pairs, but 17% differed by at least 0.5 cm. For intraobserver pairs of central CT remeasurements (n = 70), 90% differed by 0.2 cm or less, 70% were within 0.1 cm, and only one differed by 0.5 cm. Of 258 ultrasound-measured and central CT pairs, the difference was 0.2 cm or less in 44% and at least 0.5 cm in 33%. Ultrasound measurements were smaller than central CT measurements by an average of 0.27 cm (p < 0.0001). Local CT and ultrasound measurements showed a marked preference for recording by half centimeter.
CONCLUSIONS: A high degree of precision is possible in CT measurement of AAA diameter, but this precision may not be obtained in practice because of differences in measurement techniques. Differences between imaging modalities increase variability further. Variations in AAA measurement of 0.5 cm or more are not uncommon, and this should be taken into account in management decisions. Efforts to reduce variation in measurement are warranted and might include (1) seeking agreement between surgeons and radiologists on a precise definition of AAA diameter, (2) limiting the number of radiologists who measure AAAs, and (3) use of calipers and magnifying glass for CT measurements.
METHODS: CT measurements of AAA diameter from participating centers were compared with measurements made from the same scan by a central laboratory. Blinded central remeasurement of a randomly selected subset of these CT scans was used to assess intraobserver variability. Agreement between AAA measurements by CT and ultrasonography done within 30 days of each other was also assessed.
RESULTS: For interobserver pairs of local and central CT measurements of AAA diameter (n = 806), the difference was 0.2 cm or less in 65% of pairs, but 17% differed by at least 0.5 cm. For intraobserver pairs of central CT remeasurements (n = 70), 90% differed by 0.2 cm or less, 70% were within 0.1 cm, and only one differed by 0.5 cm. Of 258 ultrasound-measured and central CT pairs, the difference was 0.2 cm or less in 44% and at least 0.5 cm in 33%. Ultrasound measurements were smaller than central CT measurements by an average of 0.27 cm (p < 0.0001). Local CT and ultrasound measurements showed a marked preference for recording by half centimeter.
CONCLUSIONS: A high degree of precision is possible in CT measurement of AAA diameter, but this precision may not be obtained in practice because of differences in measurement techniques. Differences between imaging modalities increase variability further. Variations in AAA measurement of 0.5 cm or more are not uncommon, and this should be taken into account in management decisions. Efforts to reduce variation in measurement are warranted and might include (1) seeking agreement between surgeons and radiologists on a precise definition of AAA diameter, (2) limiting the number of radiologists who measure AAAs, and (3) use of calipers and magnifying glass for CT measurements.
Full text links
Related Resources
Trending Papers
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Anti-Arrhythmic Effects of Heart Failure Guideline-Directed Medical Therapy and Their Role in the Prevention of Sudden Cardiac Death: From Beta-Blockers to Sodium-Glucose Cotransporter 2 Inhibitors and Beyond.Journal of Clinical Medicine 2024 Februrary 27
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app