JOURNAL ARTICLE

Observations on pleural fluid pressures as fluid is withdrawn during thoracentesis

R W Light, S G Jenkinson, V D Minh, R B George
American Review of Respiratory Disease 1980, 121 (5): 799-804
7406313
In 52 patients with pleural effusions, pleural pressures were measured initially and serially as pleural fluid was withdrawn. Pleural fluid aspiration was continued until the pleural pressure fell below -20 cmH2O, or the patient developed excessive symptoms, or no more fluid could be obtained. The initial pleural pressure ranged from +8 to -21 cmH2O. The rate of pleural pressure change as fluid was withdrawn was highly variable. In 13 of 52 procedures (25%), thoracentesis was terminated because the pressure fell below -20 cmH2O. Negative initial pleural pressures and/or rapid changes in the pressures as fluid was withdrawn were suggestive of malignancy or trapped lung. The measurement of pleural pressures in patients with pleural effusions may be useful diagnostically. More importantly, because large changes in pleural pressures are not readily detectable by the operator, pleural pressures should be monitored when large amounts (> 1,000 ml) of pleural fluid are removed to increase the safety of the procedure.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Trending Papers

Remove bar
Read by QxMD icon Read
7406313
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"