Add like
Add dislike
Add to saved papers

Ultrasonic evaluation of neonatal intracranial hemorrhage and its complications.

Radiology 1981 June
High resolution, real-time ultrasound scans were obtained through the anterior fontanelle to examine the intracranial anatomy of 100 neonates. Of 43 patients with abnormalities, 26 had intracranial hemorrhage (subependymal, intraventricular, or cerebral). Of the 51 patients also studied by CT, the sensitivity of ultrasound in detecting hemorrhage was 96% and the specificity 94%. This ultrasound technique was also very useful for detecting complications such as porencephalic and subependymal cysts, ventricular septations, and hydrocephalus. In normal premature neonates (25 to 35 weeks gestation) the lateral ventricles appear as slit-like structures on the coronal scan. The midline-lateral dimension of normal lateral ventricles was 8.6 mm (range 7-11 mm) and the depth of 1.9 mm (range 1-3 mm). Follow-up scans in patients with intraventricular hemorrhage show that in mild hydrocephalus, the lateral ventricle becomes rounded rather than slit-like. This change occurs before the midline-lateral dimension of the ventricle increases.

Full text links

For the best experience, use the Read mobile app

Group 7SearchHeart failure treatmentPapersTopicsCollectionsEffects of Sodium-Glucose Cotransporter 2 Inhibitors for the Treatment of Patients With Heart Failure Importance: Only 1 class of glucose-lowering agents-sodium-glucose cotransporter 2 (SGLT2) inhibitors-has been reported to decrease the risk of cardiovascular events primarily by reducingSeptember 1, 2017: JAMA CardiologyAssociations of albuminuria in patients with chronic heart failure: findings in the ALiskiren Observation of heart Failure Treatment study.CONCLUSIONS: Increased UACR is common in patients with heart failure, including non-diabetics. Urinary albumin creatininineJul, 2011: European Journal of Heart FailureRandomized Controlled TrialEffects of Liraglutide on Clinical Stability Among Patients With Advanced Heart Failure and Reduced Ejection Fraction: A Randomized Clinical Trial.Review

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app