Reliability of self-measured objective functional impairment using the timed up and go test in patients with diseases of the spine.

Acta Neurochirurgica 2024 October 2
BACKGROUND: Accurate assessment of a patient's functional status is crucial for determining the need for treatment and evaluating outcomes. Objective functional impairment (OFI) measures, alongside patient-reported outcome measures (PROMs), have been proposed for spine diseases. The Timed-Up and Go (TUG) test, typically administered by healthcare professionals, is a well-studied OFI measure. This study investigates whether patient self-measurement of TUG is similarly reliable.

METHODS: In a prospective, observational study, patients with spinal diseases underwent two TUG assessments: one measured by a healthcare professional and one self-measured by the patient. Interrater reliability was assessed using the intraclass correlation coefficient (ICC) with a two-way random-effects model, considered excellent between 0.75 - 1.00. Paired t-tests directly compared both measurements. The impact of variables such as age, sex, disease type, symptom severity (via PROMs), comorbidities, and frailty on reliability was also analysed.

RESULTS: Seventy-four patients were included, with a mean age of 62.9 years (SD 17.8); 29 (39.2%) were female. The majority (64.9%) were treated for degenerative disc disease. The lumbo-sacral region was most affected (71.6%), and 47.3% had previous surgeries. Patient self-measurement reliability was excellent (ICC 0.8740, p < 0.001), and the difference between healthcare professional (19.3 ± 9.4 s) and patient measurements (18.4 ± 9.7 s) was insignificant (p = 0.116). Interrater reliability remained high in patients > 65 years (ICC 0.8584, p < 0.001), patients with ASA grades 3&4 (ICC 0.7066, p < 0.001), patients considered frail (ICC 0.8799, p < 0.001), and in patients not using any walking aid (ICC 0.8012, p < 0.001). High symptom severity still showed strong reliability (ICC 0.8279, p < 0.001 for Oswestry Disability Index > 40; ICC 0.8607, p = 0.011 for Neck Disability Index > 40).

CONCLUSIONS: Patients with spine diseases can reliably self-measure OFI using the TUG test. The interrater reliability between self-measurements and those by healthcare professionals was excellent across all conditions. These findings could optimize patient assessments, especially in resource-limited settings.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app