Biomechanical characteristics of maxillary anterior incisor, conventional immediate implantation and socket shield technique--a finite element analysis and case report.
Annals of Anatomy 2024 August 1
BACKGROUND: To prevent the absorption and collapse of the labial bone plate of the anterior teeth, immediate implantation and socket shield technique have been increasingly applied to anterior dental aesthetic implant restoration.
OBJECTIVE: To provide a biomechanical basis for implant restoration of maxillary anterior teeth, finite element analysis was used to investigate the stress peak and distribution in different anatomical sites of natural teeth, conventional immediate implantation and socket shield technique.
METHODS: Three maxillary finite element models were established, including a maxillary incisor as a natural tooth, a conventional immediate implantation and a socket shield technique. A mechanical load of 100N was applied to simulate and analyze the biomechanical behavior of the root, periodontal ligament (PDL), implant and surrounding bone interface.
RESULTS: The stress distribution of the natural tooth was relatively uniform under load. The maximum von Mises stress of the root, periodontal ligament, cortical bone and cancellous bone were 20.14MPa, 2.473MPa, 19.48MPa and 5.068MPa, respectively. When the conventional immediate implantation was loaded, the stress was mainly concentrated around the neck of implant. Maximum stress on the surface of the implant was 102MPa, the cortical bone was 16.13MPa, and the cancellous bone was 18.29MPa. When the implantation with socket shield technique was loaded, the stress distribution of the implant was similar to that of immediate implantation. Maximum stress on the surface of the implant was 100.5MPa, the cortical bone was 23.11MPa, the cancellous bone was 21.66MPa, the remaining tooth fragment was 29.42MPa and the periodontal ligament of the tooth fragment was 1.131MPa.
CONCLUSIONS: 1. Under static loading, both socket shield technology and conventional immediate implantation can support the esthetic restoration of anterior teeth biomechanically. 2.Under short-term follow-up, both immediate implant and socket shield technology achieved satisfactory clinical results, including bone healing and patient satisfaction. 3.The stress distribution is mainly located on the buccal bone surface of the implant and is associated with resorption of the buccal bone plate after implant replacement in both socket shield technology and conventional immediate implantation. 4.The presence of retained root fragment had an impact on the bone graft gap. In immediate implantation, the peak stress was located in the cortical bone near the implant position, while in socket shield technology, the peak stress was at the neck of the cortical bone corresponding to the retained root fragment.
OBJECTIVE: To provide a biomechanical basis for implant restoration of maxillary anterior teeth, finite element analysis was used to investigate the stress peak and distribution in different anatomical sites of natural teeth, conventional immediate implantation and socket shield technique.
METHODS: Three maxillary finite element models were established, including a maxillary incisor as a natural tooth, a conventional immediate implantation and a socket shield technique. A mechanical load of 100N was applied to simulate and analyze the biomechanical behavior of the root, periodontal ligament (PDL), implant and surrounding bone interface.
RESULTS: The stress distribution of the natural tooth was relatively uniform under load. The maximum von Mises stress of the root, periodontal ligament, cortical bone and cancellous bone were 20.14MPa, 2.473MPa, 19.48MPa and 5.068MPa, respectively. When the conventional immediate implantation was loaded, the stress was mainly concentrated around the neck of implant. Maximum stress on the surface of the implant was 102MPa, the cortical bone was 16.13MPa, and the cancellous bone was 18.29MPa. When the implantation with socket shield technique was loaded, the stress distribution of the implant was similar to that of immediate implantation. Maximum stress on the surface of the implant was 100.5MPa, the cortical bone was 23.11MPa, the cancellous bone was 21.66MPa, the remaining tooth fragment was 29.42MPa and the periodontal ligament of the tooth fragment was 1.131MPa.
CONCLUSIONS: 1. Under static loading, both socket shield technology and conventional immediate implantation can support the esthetic restoration of anterior teeth biomechanically. 2.Under short-term follow-up, both immediate implant and socket shield technology achieved satisfactory clinical results, including bone healing and patient satisfaction. 3.The stress distribution is mainly located on the buccal bone surface of the implant and is associated with resorption of the buccal bone plate after implant replacement in both socket shield technology and conventional immediate implantation. 4.The presence of retained root fragment had an impact on the bone graft gap. In immediate implantation, the peak stress was located in the cortical bone near the implant position, while in socket shield technology, the peak stress was at the neck of the cortical bone corresponding to the retained root fragment.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app