We have located links that may give you full text access.
A Feasibility Study of AI-Assisted Compressed Sensing in Prostate T2-Weighted Imaging.
Academic Radiology 2024 July 26
RATIONALE AND OBJECTIVES: To evaluate the image quality and PI-RADS scoring performance of prostate T2-weighted imaging (T2WI) based on AI-assisted compressed sensing (ACS).
MATERIALS AND METHODS: In this prospective study, adult male urological outpatients or inpatients underwent prostate MRI, including T2WI, diffusion-weighted imaging and apparent diffusion coefficient maps. Three accelerated scanning protocols using parallel imaging (PI) and ACS: T2WIPI , T2WIACS1 and T2WIACS2 were evaluated through comparative analysis. Quantitative analysis included signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), slope profile, and edge rise distance (ERD). Image quality was qualitatively assessed using a five-point Likert scale (ranging from 1 = non-diagnostic to 5 = excellent). PI-RADS scores were determined for the largest or most suspicious lesions in each patient. The Friedman test and one-way ANOVA with post hoc tests were utilized for group comparisons, with statistical significance set at P < 0.05.
RESULTS: This study included 40 participants. Compared to PI, ACS reduced acquisition time by over 50%, significantly enhancing the CNR of sagittal and axial T2WI (P < 0.05), significantly improving the image quality of sagittal and axial T2WI (P < 0.05). No significant differences were observed in slope profile, ERD, and PI-RADS scores between groups (P > 0.05).
CONCLUSION: ACS reduced prostate T2WI acquisition time by half while improving image quality without affecting PI-RADS scores.
MATERIALS AND METHODS: In this prospective study, adult male urological outpatients or inpatients underwent prostate MRI, including T2WI, diffusion-weighted imaging and apparent diffusion coefficient maps. Three accelerated scanning protocols using parallel imaging (PI) and ACS: T2WIPI , T2WIACS1 and T2WIACS2 were evaluated through comparative analysis. Quantitative analysis included signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), slope profile, and edge rise distance (ERD). Image quality was qualitatively assessed using a five-point Likert scale (ranging from 1 = non-diagnostic to 5 = excellent). PI-RADS scores were determined for the largest or most suspicious lesions in each patient. The Friedman test and one-way ANOVA with post hoc tests were utilized for group comparisons, with statistical significance set at P < 0.05.
RESULTS: This study included 40 participants. Compared to PI, ACS reduced acquisition time by over 50%, significantly enhancing the CNR of sagittal and axial T2WI (P < 0.05), significantly improving the image quality of sagittal and axial T2WI (P < 0.05). No significant differences were observed in slope profile, ERD, and PI-RADS scores between groups (P > 0.05).
CONCLUSION: ACS reduced prostate T2WI acquisition time by half while improving image quality without affecting PI-RADS scores.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app