We have located links that may give you full text access.
Amplitude Parameters Are Predictive of Hearing Preservation in a Randomized Controlled Trial of Intracochlear Electrocochleography During Cochlear Implant Surgery.
Otology & Neurotology 2024 July 25
OBJECTIVE: To prospectively evaluate the association between hearing preservation after cochlear implantation (CI) and intracochlear electrocochleography (ECochG) amplitude parameters.
STUDY DESIGN: Multi-institutional, prospective randomized clinical trial.
SETTING: Ten high-volume, tertiary care CI centers.
PATIENTS: Adults (n = 87) with sensorineural hearing loss meeting CI criteria (2018-2021) with audiometric thresholds of ≤80 dB HL at 500 Hz.
METHODS: Participants were randomized to CI surgery with or without audible ECochG monitoring. Electrode arrays were inserted to the full-depth marker. Hearing preservation was determined by comparing pre-CI, unaided low-frequency (125-, 250-, and 500-Hz) pure-tone average (LF-PTA) to LF-PTA at CI activation. Three ECochG amplitude parameters were analyzed: 1) insertion track patterns, 2) magnitude of ECochG amplitude change, and 3) total number of ECochG amplitude drops.
RESULTS: The Type CC insertion track pattern, representing corrected drops in ECochG amplitude, was seen in 76% of cases with ECochG "on," compared with 24% of cases with ECochG "off" (p = 0.003). The magnitude of ECochG signal drop was significantly correlated with the amount of LF-PTA change pre-CI and post-CI (p < 0.05). The mean number of amplitude drops during electrode insertion was significantly correlated with change in LF-PTA at activation and 3 months post-CI (p ≤ 0.01).
CONCLUSIONS: ECochG amplitude parameters during CI surgery have important prognostic utility. Higher incidence of Type CC in ECochG "on" suggests that monitoring may be useful for surgeons in order to recover the ECochG signal and preventing potentially traumatic electrode-cochlear interactions.
STUDY DESIGN: Multi-institutional, prospective randomized clinical trial.
SETTING: Ten high-volume, tertiary care CI centers.
PATIENTS: Adults (n = 87) with sensorineural hearing loss meeting CI criteria (2018-2021) with audiometric thresholds of ≤80 dB HL at 500 Hz.
METHODS: Participants were randomized to CI surgery with or without audible ECochG monitoring. Electrode arrays were inserted to the full-depth marker. Hearing preservation was determined by comparing pre-CI, unaided low-frequency (125-, 250-, and 500-Hz) pure-tone average (LF-PTA) to LF-PTA at CI activation. Three ECochG amplitude parameters were analyzed: 1) insertion track patterns, 2) magnitude of ECochG amplitude change, and 3) total number of ECochG amplitude drops.
RESULTS: The Type CC insertion track pattern, representing corrected drops in ECochG amplitude, was seen in 76% of cases with ECochG "on," compared with 24% of cases with ECochG "off" (p = 0.003). The magnitude of ECochG signal drop was significantly correlated with the amount of LF-PTA change pre-CI and post-CI (p < 0.05). The mean number of amplitude drops during electrode insertion was significantly correlated with change in LF-PTA at activation and 3 months post-CI (p ≤ 0.01).
CONCLUSIONS: ECochG amplitude parameters during CI surgery have important prognostic utility. Higher incidence of Type CC in ECochG "on" suggests that monitoring may be useful for surgeons in order to recover the ECochG signal and preventing potentially traumatic electrode-cochlear interactions.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app