Real-Time Ultrasound Tip Location Reduces Malposition and Radiation Exposure during Umbilical Venous Catheter Placement in Neonates: A Retrospective, Observational Study.
Neonatology 2024 June 21
INTRODUCTION: The umbilical venous catheter is a vital access device in neonatal intensive care units for preterm and critically ill infants. Correct positioning is crucial, as malpositioning can lead to severe complications. According to international guidelines, the position of the umbilical venous catheter tip must be assessed in real time; traditionally, the catheter is visualized with a thoracoabdominal X-ray, but one of the most effective and safest methods is therefore real-time ultrasound.
METHODS: This study compares real-time ultrasound and traditional X-ray methods for assessing umbilical venous catheter tip location in 461 cases. The rate of tip malposition was analyzed retrospectively. The secondary aim was to assess indwelling time of umbilical venous catheters and reasons of removal.
RESULTS: Real-time ultrasound tip location, found to be more reliable and efficient, demonstrated a significantly lower incidence of primary malpositioning compared to X-ray assessments (9.6 vs. 75.9%). The study also highlighted the association of real-time ultrasound with reduced catheter manipulation, fewer radiographs, and higher indwelling times of umbilical venous catheter. The multiple logistic regression showed a high probability of the central safe position of the umbilical venous catheter tip using real-time ultrasound tip location (odds ratio 29.5, 95% confidence interval: 17.4-49.4).
CONCLUSION: The findings support the adoption of real-time ultrasound in clinical settings to enhance umbilical venous catheter placement accuracy and minimize associated risks. A minimal training investment is needed to attain the proficiency to visualize the umbilical venous catheters, offering a substantial advantage in terms of both cost-effectiveness for the procedure and enhanced patient safety.
METHODS: This study compares real-time ultrasound and traditional X-ray methods for assessing umbilical venous catheter tip location in 461 cases. The rate of tip malposition was analyzed retrospectively. The secondary aim was to assess indwelling time of umbilical venous catheters and reasons of removal.
RESULTS: Real-time ultrasound tip location, found to be more reliable and efficient, demonstrated a significantly lower incidence of primary malpositioning compared to X-ray assessments (9.6 vs. 75.9%). The study also highlighted the association of real-time ultrasound with reduced catheter manipulation, fewer radiographs, and higher indwelling times of umbilical venous catheter. The multiple logistic regression showed a high probability of the central safe position of the umbilical venous catheter tip using real-time ultrasound tip location (odds ratio 29.5, 95% confidence interval: 17.4-49.4).
CONCLUSION: The findings support the adoption of real-time ultrasound in clinical settings to enhance umbilical venous catheter placement accuracy and minimize associated risks. A minimal training investment is needed to attain the proficiency to visualize the umbilical venous catheters, offering a substantial advantage in terms of both cost-effectiveness for the procedure and enhanced patient safety.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2025 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app