We have located links that may give you full text access.
Superior vena cava isolation using a pentaspline pulsed-field ablation catheter: feasibility and safety in patients undergoing atrial fibrillation catheter ablation.
AIMS: Superior vena cava (SVC) isolation during atrial fibrillation (AF) catheter ablation is limited by the risk of collateral damage to the sinus node and/or the phrenic nerve. Due to its tissue-specificity, we hypothesized the feasibility and safety of pulsed-field ablation (PFA)-based SVC isolation.
METHODS AND RESULTS: A hundred and five consecutive patients undergoing PFA-based AF catheter ablation were prospectively included. After pulmonary vein isolation (± posterior wall isolation and electrical cardioversion), SVC isolation was performed using a standardized workflow. Acute SVC isolation was achieved in 105/105 (100%) patients after 6 ± 1 applications. Transient phrenic nerve stunning occurred in 67/105 (64%) patients but without phenic nerve palsy at the end of the procedure and at hospital discharge. Transient high degree sinus node dysfunction occurred in 5/105 (4.7%) patients, with no recurrence at the end of the procedure and until discharge. At the 3-month follow-up visit, no complication occurred.
CONCLUSION: SVC isolation using a pentaspline PFA catheter is feasible and safe.
METHODS AND RESULTS: A hundred and five consecutive patients undergoing PFA-based AF catheter ablation were prospectively included. After pulmonary vein isolation (± posterior wall isolation and electrical cardioversion), SVC isolation was performed using a standardized workflow. Acute SVC isolation was achieved in 105/105 (100%) patients after 6 ± 1 applications. Transient phrenic nerve stunning occurred in 67/105 (64%) patients but without phenic nerve palsy at the end of the procedure and at hospital discharge. Transient high degree sinus node dysfunction occurred in 5/105 (4.7%) patients, with no recurrence at the end of the procedure and until discharge. At the 3-month follow-up visit, no complication occurred.
CONCLUSION: SVC isolation using a pentaspline PFA catheter is feasible and safe.
Full text links
Related Resources
Trending Papers
Light chain deposition disease: pathogenesis, clinical characteristics and treatment strategies.Annals of Hematology 2024 August 28
Hodgkin lymphoma: 2025 update on diagnosis, risk-stratification, and management.American Journal of Hematology 2024 September 6
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app