Optic disc morphology and interocular symmetry in children.
PURPOSE: The purpose of the study was to obtain a pediatric reference database for optic disc parameters and interocular symmetry. To ascertain factors that modify these parameters (age, spherical equivalent [SE], and sex).
METHODS: This was a cross-sectional study. 90 patients aged 5-17 years fulfilled all the inclusion criteria. After a full examination including cycloplegic refraction, all patients underwent optical coherence tomography (OCT) of the papilla using the three-dimensional (3D) scan protocol of the Topcon 3D 2000 OCT device. We provide reference values for optic disc parameters in the pediatric population. We also retrieved interocular symmetry reference values for these parameters.
RESULTS: The multivariate regression analysis did not reveal variations in any of the optic disc parameters associated with age, sex, or SE (all P ≥ 0.126). The 95th percentile limit for absolute interocular differences for the cup-to-disc area ratio was 0.24. The multivariate regression analysis revealed the absence of a correlation between asymmetry of the optic disc parameters and age, sex, and the interocular difference in SE (all P ≥ 0.105).
CONCLUSION: Pediatric reference databases for optic disc parameters and ranges of normality for interocular symmetry provide key diagnostic support in diseases that affect the optic nerve.
METHODS: This was a cross-sectional study. 90 patients aged 5-17 years fulfilled all the inclusion criteria. After a full examination including cycloplegic refraction, all patients underwent optical coherence tomography (OCT) of the papilla using the three-dimensional (3D) scan protocol of the Topcon 3D 2000 OCT device. We provide reference values for optic disc parameters in the pediatric population. We also retrieved interocular symmetry reference values for these parameters.
RESULTS: The multivariate regression analysis did not reveal variations in any of the optic disc parameters associated with age, sex, or SE (all P ≥ 0.126). The 95th percentile limit for absolute interocular differences for the cup-to-disc area ratio was 0.24. The multivariate regression analysis revealed the absence of a correlation between asymmetry of the optic disc parameters and age, sex, and the interocular difference in SE (all P ≥ 0.105).
CONCLUSION: Pediatric reference databases for optic disc parameters and ranges of normality for interocular symmetry provide key diagnostic support in diseases that affect the optic nerve.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app