Journal Article
Validation Study
Add like
Add dislike
Add to saved papers

Reliability and validity of the medial standing overhead arm reach (SOAR) test as a measure of functional hip adduction motion.

OBJECTIVE: The Posterior Standing Overhead Arm Reach (SOAR) test has been previously reported as a reliable clinical measure of closed chain hip extension motion. The proposed Medial SOAR test expands on that testing approach to provide a similar measure of functional hip adduction motion. This was a preliminary intrarater and interrater reliability and validity study of the Medial SOAR test as a measure of functional hip adduction.

DESIGN: Cross-sectional.

SETTING: University motion analysis laboratory.

PARTICIPANTS: Fifty hips were assessed in 25 (22 female) asymptomatic participants (mean age = 23.4 years, SD = 0.8).

MAIN MEASURES: Maximum hip adduction during the Medial SOAR test was measured with a standard goniometer independently by two examiners. The test was also performed using three-dimensional motion capture. The intrarater and interrater reliability of the goniometric measure was determined using intraclass correlation coefficients, and the relationship between measures obtained via goniometry and three-dimensional motion capture was assessed with Pearson correlations and Bland-Altman analysis.

RESULTS: Intrarater reliability (ICC2,3 ) was 0.88 (95% CI = 0.80-0.92) for Examiner 1 and 0.87 (95% CI = 0.79-0.92) for Examiner 2. The standard error of measurement and minimal detectable change were less than 3.0°. Interrater reliability demonstrated an intraclass correlation coefficient = 0.62 (95% CI = 0.28-0.79). Pearson correlations were significant with low-to-moderate associations (r = 0.49, P  < 0.001; r = 0.24, P  = 0.045).

CONCLUSIONS: Similar to the previously reported Posterior SOAR test, the Medial SOAR test demonstrated acceptable intrarater and interrater reliability, along with low-to-moderate associations with three-dimensional motion capture. The Medial SOAR test has the potential to provide a reliable and accurate assessment of closed chain hip adduction.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app