We have located links that may give you full text access.
Effect of Cement Type on Fracture Resistance and Mode of Failure of Monolith vs Bilayered Zirconia Single Crowns.
Journal of Contemporary Dental Practice 2023 August 1
AIM: To compare the fracture resistance and the mode of failure between monolith second-generation zirconia and bilayered first-generation zirconia single crowns cemented by resin cement and glass ionomer cement (GIC).
MATERIALS AND METHODS: A total of 36 maxillary first premolar crowns (5 mm in length × 4 mm in cervical diameter, with a base of 6 mm) were computer-aided design-computer-aided manufacturing (CAD-CAM) milled. They were divided into the following two groups ( n = 18) according to the fabrication techniques: Group M - monolith zirconia crown (1-mm axial thickness and 2-mm occlusal thickness) and group B - bilayer zirconia crown (0.5-mm axial thickness and 1-mm occlusal thickness). Each group was further subdivided into the following two subgroups ( n = 9) according to the cement used: Subgroup G - cemented using GIC; subgroup R - cemented using resin cement. All crowns were cemented to their corresponding resin dies and stored in distilled water for 72 hours. Each specimen was mounted to the lower member of the universal testing machine with a load cell of 5 kN and a crosshead speed of 0.5 mm/minute. Failure modes were analyzed for fractured parts using scanning electron microscopy (SEM).
RESULTS: Subgroup MR recorded the highest fracture resistance mean value (3616 ± 347.2 N) while the BG subgroup recorded the statistically significant lowest fracture resistance mean value (1728.7 ± 115.3 N). One-way analysis of variance (ANOVA) followed by pairwise Tukey's post hoc tests revealed a statistically significant difference ( p = 0.0001) between groups M and B. One-way ANOVA followed by pairwise Tukey's post hoc tests also showed a statistically significant difference ( p = 0.0297) between the types of cement used (subgroups G and R).
CONCLUSION: Monolith zirconia crowns had better mean fracture resistance than bilayered zirconia crowns. Resin cement improved the fracture resistance compared to GIC. Monolith zirconia crowns showed bulk fracture while bilayered zirconia crowns showed chipping fracture.
CLINICAL SIGNIFICANCE: Monolith zirconia crowns present a good prosthetic alternative overcoming the veneer chipping drawback of bilayered zirconia crowns. In addition, resin cement could increase the fracture resistance of zirconia crowns.
MATERIALS AND METHODS: A total of 36 maxillary first premolar crowns (5 mm in length × 4 mm in cervical diameter, with a base of 6 mm) were computer-aided design-computer-aided manufacturing (CAD-CAM) milled. They were divided into the following two groups ( n = 18) according to the fabrication techniques: Group M - monolith zirconia crown (1-mm axial thickness and 2-mm occlusal thickness) and group B - bilayer zirconia crown (0.5-mm axial thickness and 1-mm occlusal thickness). Each group was further subdivided into the following two subgroups ( n = 9) according to the cement used: Subgroup G - cemented using GIC; subgroup R - cemented using resin cement. All crowns were cemented to their corresponding resin dies and stored in distilled water for 72 hours. Each specimen was mounted to the lower member of the universal testing machine with a load cell of 5 kN and a crosshead speed of 0.5 mm/minute. Failure modes were analyzed for fractured parts using scanning electron microscopy (SEM).
RESULTS: Subgroup MR recorded the highest fracture resistance mean value (3616 ± 347.2 N) while the BG subgroup recorded the statistically significant lowest fracture resistance mean value (1728.7 ± 115.3 N). One-way analysis of variance (ANOVA) followed by pairwise Tukey's post hoc tests revealed a statistically significant difference ( p = 0.0001) between groups M and B. One-way ANOVA followed by pairwise Tukey's post hoc tests also showed a statistically significant difference ( p = 0.0297) between the types of cement used (subgroups G and R).
CONCLUSION: Monolith zirconia crowns had better mean fracture resistance than bilayered zirconia crowns. Resin cement improved the fracture resistance compared to GIC. Monolith zirconia crowns showed bulk fracture while bilayered zirconia crowns showed chipping fracture.
CLINICAL SIGNIFICANCE: Monolith zirconia crowns present a good prosthetic alternative overcoming the veneer chipping drawback of bilayered zirconia crowns. In addition, resin cement could increase the fracture resistance of zirconia crowns.
Full text links
Related Resources
Trending Papers
Updated evidence on cardiovascular and renal effects of GLP-1 receptor agonists and combination therapy with SGLT2 inhibitors and finerenone: a narrative review and perspectives.Cardiovascular Diabetology 2024 November 15
Guidelines for the Prevention, Diagnosis, and Management of Urinary Tract Infections in Pediatrics and Adults: A WikiGuidelines Group Consensus Statement.JAMA Network Open 2024 November 4
Autoantibodies in neuromuscular disorders: a review of their utility in clinical practice.Frontiers in Neurology 2024
Methods for determining optimal positive end-expiratory pressure in patients undergoing invasive mechanical ventilation: a scoping review.Canadian Journal of Anaesthesia 2024 November 20
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app