Mean distance from skin to epiglottis in parturients as measured by airway ultrasound.
INTRODUCTION: There is an increasing interest in using airway ultrasound to predict difficult intubation. Studies to date have excluded pregnant women in reporting airway measurements. We performed this study to compare the mean distance from skin to epiglottis in parturients to that reported in previously published studies. We also assessed the correlation of mean distance from skin to epiglottis with other elements of the airway examination.
METHODS: A total of 100 parturients were recruited from a tertiary hospital's labor and delivery floor. Standard physical examination parameters were recorded in addition to the mean distance from skin to epiglottis for all subjects. The ratio of height-to-thyromental distance was used to classify airways as potentially favorable or unfavorable.
RESULTS: The average mean distance from skin to epiglottis in parturients was 19.9 ± 3.3 mm and followed a normal distribution. The mean distance from skin to epiglottis was moderately correlated with height and body mass index. There was no difference in mean distance from skin to epiglottis between subjects with favorable versus unfavorable airways as classified by ratio of height-to-thyromental distance.
CONCLUSION: The typical mean distance from skin to epiglottis in parturients falls between previously published values in mixed populations. Previously published cut-off values using airway ultrasound to predict difficult intubation are not likely to apply to parturients.
METHODS: A total of 100 parturients were recruited from a tertiary hospital's labor and delivery floor. Standard physical examination parameters were recorded in addition to the mean distance from skin to epiglottis for all subjects. The ratio of height-to-thyromental distance was used to classify airways as potentially favorable or unfavorable.
RESULTS: The average mean distance from skin to epiglottis in parturients was 19.9 ± 3.3 mm and followed a normal distribution. The mean distance from skin to epiglottis was moderately correlated with height and body mass index. There was no difference in mean distance from skin to epiglottis between subjects with favorable versus unfavorable airways as classified by ratio of height-to-thyromental distance.
CONCLUSION: The typical mean distance from skin to epiglottis in parturients falls between previously published values in mixed populations. Previously published cut-off values using airway ultrasound to predict difficult intubation are not likely to apply to parturients.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app