We have located links that may give you full text access.
Precise localization of microvascular invasion in hepatocellular carcinoma based on three-dimensional histology-MR image fusion: an ex vivo experimental study.
Quantitative Imaging in Medicine and Surgery 2023 September 1
BACKGROUND: Microvascular invasion (MVI) is an independent risk factor for postoperative recurrence of hepatocellular carcinoma (HCC). However, MVI cannot be detected by conventional imaging. To localize MVI precisely on magnetic resonance (MR) images, we evaluated the feasibility and accuracy of 3-dimensional (3D) histology-MR image fusion of the liver.
METHODS: Animal models of VX2 liver tumors were established in 10 New Zealand white rabbits under ultrasonographic guidance. The whole liver lobe containing the VX2 tumor was extracted and divided into 4 specimens, for a total of 40 specimens. MR images were obtained with a T2-weighted sequence for each specimen, and then histological images were obtained by intermittent, serial pathological sections. 3D histology-MR image fusion was performed via landmark registration in 3D Slicer software. We calculated the success rate and registration errors of image fusion, and then we located the MVI on MR images. Regarding influencing factors, we evaluated the uniformity of tissue thickness after sampling and the uniformity of tissue shrinkage after dehydration.
RESULTS: The VX2 liver tumor model was successfully established in the 10 rabbits. The incidence of MVI was 80% (8/10). 3D histology-MR image fusion was successfully performed in the 39 specimens, and the success rate was 97.5% (39/40). The average registration error was 0.44±0.15 mm. MVI was detected in 20 of the 39 successfully registered specimens, resulting in a total of 166 MVI lesions. The specific location of all MVI lesions was accurately identified on MR images using 3D histology-MR image fusion. All MVI lesions showed as slightly hyperintense on the high-resolution MR T2-weighted images. The results of the influencing factor assessment showed that the tissue thickness was uniform after sampling (P=0.38), but the rates of the tissue shrinkage was inconsistent after dehydration (P<0.001).
CONCLUSIONS: 3D histology-MR image fusion of the isolated liver tumor model is feasible and accurate and allows for the successful identification of the specific location of MVI on MR images.
METHODS: Animal models of VX2 liver tumors were established in 10 New Zealand white rabbits under ultrasonographic guidance. The whole liver lobe containing the VX2 tumor was extracted and divided into 4 specimens, for a total of 40 specimens. MR images were obtained with a T2-weighted sequence for each specimen, and then histological images were obtained by intermittent, serial pathological sections. 3D histology-MR image fusion was performed via landmark registration in 3D Slicer software. We calculated the success rate and registration errors of image fusion, and then we located the MVI on MR images. Regarding influencing factors, we evaluated the uniformity of tissue thickness after sampling and the uniformity of tissue shrinkage after dehydration.
RESULTS: The VX2 liver tumor model was successfully established in the 10 rabbits. The incidence of MVI was 80% (8/10). 3D histology-MR image fusion was successfully performed in the 39 specimens, and the success rate was 97.5% (39/40). The average registration error was 0.44±0.15 mm. MVI was detected in 20 of the 39 successfully registered specimens, resulting in a total of 166 MVI lesions. The specific location of all MVI lesions was accurately identified on MR images using 3D histology-MR image fusion. All MVI lesions showed as slightly hyperintense on the high-resolution MR T2-weighted images. The results of the influencing factor assessment showed that the tissue thickness was uniform after sampling (P=0.38), but the rates of the tissue shrinkage was inconsistent after dehydration (P<0.001).
CONCLUSIONS: 3D histology-MR image fusion of the isolated liver tumor model is feasible and accurate and allows for the successful identification of the specific location of MVI on MR images.
Full text links
Related Resources
Trending Papers
2024 AHA/ACC/ACS/ASNC/HRS/SCA/SCCT/SCMR/SVM Guideline for Perioperative Cardiovascular Management for Noncardiac Surgery: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines.Circulation 2024 September 24
Pathophysiology and Treatment of Prediabetes and Type 2 Diabetes in Youth.Diabetes Care 2024 September 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app