We have located links that may give you full text access.
Usefulness of attenuation value on computed tomography plain scan for diagnosing enlarged mediastinal lymph nodes metastases.
Quantitative Imaging in Medicine and Surgery 2023 September 1
BACKGROUND: To evaluate the diagnostic value of computed tomography (CT) attenuation in mediastinal lymph node metastases of malignant tumors.
METHODS: A retrospective review was conducted of a Chinese institutional database of consecutive patients with a history of malignant tumors. Those who had enlarged, necrotic, or hypermetabolic lymph nodes detected in the mediastinum during routine CT examination or positron emission tomography (PET)/CT imaging from January 2019 to December 2021 were collected for investigation. All patients underwent endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) and were followed up for at least 6 months to diagnose lymph node metastases. One-to-one correlation was attempted between the CT images of the lymph nodes and EBUS-TBNA area of the same lymph node groups and similar size. Radiologists measured size, as well as plain CT and contrast-enhanced CT (CECT) attenuation values of mediastinal lymph nodes, and evaluated the effectiveness of these variables in diagnosing lymph node metastasis.
RESULTS: A total of 135 lymph nodes of 114 patients were included in the study. In the univariate analysis, the long-axis diameter, short-axis diameter, short-axis/long-axis ratio, and plain CT attenuation values of lymph nodes were found to be statistically significantly different between the metastatic and non-metastatic lymph nodes. The areas under receiver operator characteristic (ROC) curves (AUCs) of long-axis diameter, short-axis diameter, short-axis/long-axis ratio, and plain CT attenuation value for diagnosing metastases were 0.711, 0.788, 0.671, and 0.827, respectively. The best value of the AUC for diagnosing lymph node metastases was 0.827 [95% confidence interval (CI): 0.749-0.890] using plain CT attenuation value ≤45 Hounsfield units (HU). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 92.8%, 69.2%, 86.5%, and 81.8%, respectively. Similar results were obtained from the 68 cases of lung cancer. Plain CT attenuation values reached the best AUC (0.860) for diagnosing lymph node metastases.
CONCLUSIONS: Plain CT attenuation of lymph nodes is an effective method for diagnosing enlarged mediastinal lymph nodes with a history of multiple malignancies or lung cancer. Plain CT could be used as an additional test where there is no PET/CT available in cases of diagnostic dilemma.
METHODS: A retrospective review was conducted of a Chinese institutional database of consecutive patients with a history of malignant tumors. Those who had enlarged, necrotic, or hypermetabolic lymph nodes detected in the mediastinum during routine CT examination or positron emission tomography (PET)/CT imaging from January 2019 to December 2021 were collected for investigation. All patients underwent endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) and were followed up for at least 6 months to diagnose lymph node metastases. One-to-one correlation was attempted between the CT images of the lymph nodes and EBUS-TBNA area of the same lymph node groups and similar size. Radiologists measured size, as well as plain CT and contrast-enhanced CT (CECT) attenuation values of mediastinal lymph nodes, and evaluated the effectiveness of these variables in diagnosing lymph node metastasis.
RESULTS: A total of 135 lymph nodes of 114 patients were included in the study. In the univariate analysis, the long-axis diameter, short-axis diameter, short-axis/long-axis ratio, and plain CT attenuation values of lymph nodes were found to be statistically significantly different between the metastatic and non-metastatic lymph nodes. The areas under receiver operator characteristic (ROC) curves (AUCs) of long-axis diameter, short-axis diameter, short-axis/long-axis ratio, and plain CT attenuation value for diagnosing metastases were 0.711, 0.788, 0.671, and 0.827, respectively. The best value of the AUC for diagnosing lymph node metastases was 0.827 [95% confidence interval (CI): 0.749-0.890] using plain CT attenuation value ≤45 Hounsfield units (HU). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 92.8%, 69.2%, 86.5%, and 81.8%, respectively. Similar results were obtained from the 68 cases of lung cancer. Plain CT attenuation values reached the best AUC (0.860) for diagnosing lymph node metastases.
CONCLUSIONS: Plain CT attenuation of lymph nodes is an effective method for diagnosing enlarged mediastinal lymph nodes with a history of multiple malignancies or lung cancer. Plain CT could be used as an additional test where there is no PET/CT available in cases of diagnostic dilemma.
Full text links
Related Resources
Trending Papers
Novel Insights into Diabetic Kidney Disease.International Journal of Molecular Sciences 2024 September 23
Perioperative fluid management: evidence-based consensus recommendations from the international multidisciplinary PeriOperative Quality Initiative.British Journal of Anaesthesia 2024 September 27
Sodium-glucose cotransporter-2 (SGLT-2) inhibitors for adults with chronic kidney disease: a clinical practice guideline.BMJ : British Medical Journal 2024 October 1
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app