We have located links that may give you full text access.
Artificial Intelligence for Assessment of Endotracheal Tube Position on Chest Radiographs: Validation in Patients From Two Institutions.
AJR. American Journal of Roentgenology 2023 September 14
Background: Timely and accurate interpretation of chest radiographs obtained to evaluate endotracheal tube (ETT) position is important for facilitating prompt adjustment if needed. Objective: To evaluate the performance of a deep learning (DL)-based artificial intelligence (AI) system for detecting ETT presence and position on chest radiographs in three patient samples from two different institutions. Methods: This retrospective study included 539 chest radiographs obtained immediately after ETT insertion from January 1, 2020 to March 31, 2020 in 505 patients (293 men, 212 women; mean age, 63 years) from institution A (sample A); 637 chest radiographs obtained from January 1, 2020 to January 3, 2020 in 304 patients (158 men, 147 women; mean age, 63 years) in the ICU (with or without an ETT) from institution A (sample B); and 546 chest radiographs obtained from January 1, 2020 to January 20, 2020 in 83 patients (54 men, 29 women; mean age, 70 years) in the ICU (with or without an ETT) from institution B (sample C). A commercial DL-based AI system was used to identify ETT presence and measure ETT tip-to-carina distance (TCD). Reference standard for proper ETT position was TCD between 3 cm and 7 cm, determined by human readers. Critical ETT position was separately defined as ETT tip below the carina or TCD ≤1 cm. ROC analysis was performed. Results: AI had sensitivity and specificity for identification of ETT presence of 100.0% and 98.7% (sample B) and 99.2% and 94.5% (sample C). AI had sensitivity and specificity for identification of improper ETT position of 72.5% and 92.0% (sample A), 78.9% and 100.0% (sample B), and 83.7% and 99.1% (sample C). At threshold y-axis TCD ≤2 cm, AI had sensitivity and specificity for critical ETT position of 100.0% and 96.7% (sample A), 100.0% and 100.0% (sample B), and 100.0% and 99.2% (sample C). Conclusion: AI identified improperly positioned ETTs on chest radiographs obtained after ETT insertion, as well as on chest radiographs obtained from patients in the ICU at two institutions. Clinical Impact: Automated AI identification of improper ETT position on chest radiograph may allow earlier repositioning and thereby reduce complications.
Full text links
Related Resources
Trending Papers
Clinical guideline on reversal of direct oral anticoagulants in patients with life threatening bleeding.European Journal of Anaesthesiology 2024 May 2
Aspiration under anesthesia: what happens after we sound the glucagon-like peptide-1 receptor agonist alarm?Canadian Journal of Anaesthesia 2024 August 27
Perioperative Management of Patients Taking Direct Oral Anticoagulants: A Review.JAMA 2024 August 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app