BACKGROUND: Although current research revealed the preoperative diameter of the aorta is related to aortic remodeling, prognosis should consider the true lumen (TL) and false lumen (FL) respectively too.
METHODS: The cohort of this retrospective analysis included 161 type A aortic dissection (TAAD) patients who underwent surgery at a single institution from September 1, 2017, to September 1, 2018. Computed tomography angiography (CTA) images were reviewed to assess changes of the diameters of the TL, FL and total aorta at the levels of the stented segment, distal end of the stent, celiac trunk, and below the renal artery.
RESULTS: During the study period, positive remodeling was observed in 33 (20.5%) patients. The probability of negative remodeling far from the stent segment was greater than the aorta close to the stent. Only the TL diameter was associated with each levels' changes and underwent significant change (P<0.05). Multivariate analysis identified aortic regurgitation as a risk factor for remodeling in the distal end of the stent. The maximum diameter of the FL was the only risk factor related to the remodeling type (odds ratio =0.10; 95% confidence interval: 0.01-0.51), a maximum diameter of the FL of >1.28 cm was associated with a higher probability of negative remodeling after surgery (specificity =0.994; sensitivity =0.571; area under the receiver operating characteristic curve =0.76).
CONCLUSIONS: The TL and FL diameters on preoperative CTA images can be used to assess the risk of negative remodeling after surgery.
METHODS: The cohort of this retrospective analysis included 161 type A aortic dissection (TAAD) patients who underwent surgery at a single institution from September 1, 2017, to September 1, 2018. Computed tomography angiography (CTA) images were reviewed to assess changes of the diameters of the TL, FL and total aorta at the levels of the stented segment, distal end of the stent, celiac trunk, and below the renal artery.
RESULTS: During the study period, positive remodeling was observed in 33 (20.5%) patients. The probability of negative remodeling far from the stent segment was greater than the aorta close to the stent. Only the TL diameter was associated with each levels' changes and underwent significant change (P<0.05). Multivariate analysis identified aortic regurgitation as a risk factor for remodeling in the distal end of the stent. The maximum diameter of the FL was the only risk factor related to the remodeling type (odds ratio =0.10; 95% confidence interval: 0.01-0.51), a maximum diameter of the FL of >1.28 cm was associated with a higher probability of negative remodeling after surgery (specificity =0.994; sensitivity =0.571; area under the receiver operating characteristic curve =0.76).
CONCLUSIONS: The TL and FL diameters on preoperative CTA images can be used to assess the risk of negative remodeling after surgery.
Full text links
Related Resources
Trending Papers
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app