We have located links that may give you full text access.
Preoperative diameters of aorta influence the remodeling after surgery for type A aortic dissection.
Journal of Thoracic Disease 2023 August 32
BACKGROUND: Although current research revealed the preoperative diameter of the aorta is related to aortic remodeling, prognosis should consider the true lumen (TL) and false lumen (FL) respectively too.
METHODS: The cohort of this retrospective analysis included 161 type A aortic dissection (TAAD) patients who underwent surgery at a single institution from September 1, 2017, to September 1, 2018. Computed tomography angiography (CTA) images were reviewed to assess changes of the diameters of the TL, FL and total aorta at the levels of the stented segment, distal end of the stent, celiac trunk, and below the renal artery.
RESULTS: During the study period, positive remodeling was observed in 33 (20.5%) patients. The probability of negative remodeling far from the stent segment was greater than the aorta close to the stent. Only the TL diameter was associated with each levels' changes and underwent significant change (P<0.05). Multivariate analysis identified aortic regurgitation as a risk factor for remodeling in the distal end of the stent. The maximum diameter of the FL was the only risk factor related to the remodeling type (odds ratio =0.10; 95% confidence interval: 0.01-0.51), a maximum diameter of the FL of >1.28 cm was associated with a higher probability of negative remodeling after surgery (specificity =0.994; sensitivity =0.571; area under the receiver operating characteristic curve =0.76).
CONCLUSIONS: The TL and FL diameters on preoperative CTA images can be used to assess the risk of negative remodeling after surgery.
METHODS: The cohort of this retrospective analysis included 161 type A aortic dissection (TAAD) patients who underwent surgery at a single institution from September 1, 2017, to September 1, 2018. Computed tomography angiography (CTA) images were reviewed to assess changes of the diameters of the TL, FL and total aorta at the levels of the stented segment, distal end of the stent, celiac trunk, and below the renal artery.
RESULTS: During the study period, positive remodeling was observed in 33 (20.5%) patients. The probability of negative remodeling far from the stent segment was greater than the aorta close to the stent. Only the TL diameter was associated with each levels' changes and underwent significant change (P<0.05). Multivariate analysis identified aortic regurgitation as a risk factor for remodeling in the distal end of the stent. The maximum diameter of the FL was the only risk factor related to the remodeling type (odds ratio =0.10; 95% confidence interval: 0.01-0.51), a maximum diameter of the FL of >1.28 cm was associated with a higher probability of negative remodeling after surgery (specificity =0.994; sensitivity =0.571; area under the receiver operating characteristic curve =0.76).
CONCLUSIONS: The TL and FL diameters on preoperative CTA images can be used to assess the risk of negative remodeling after surgery.
Full text links
Trending Papers
Restrictive fluid resuscitation in septic shock patients has lower mortality and organ dysfunction rates than standard therapy.Shock 2023 November 11
Cardiovascular Disease in Diabetes and Chronic Kidney Disease.Journal of Clinical Medicine 2023 November 9
Euglycemic Ketoacidosis in Two Patients Without Diabetes After Introduction of Sodium-Glucose Cotransporter 2 Inhibitor for Heart Failure With Reduced Ejection Fraction.Diabetes Care 2023 November 22
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app