Add like
Add dislike
Add to saved papers

Risk assessment of the asthma-induction potential of substances in spray products for car cabin detailing - based on EU's Chemical Agents Directive, using harmonised classifications and quantitative structure-activity relationship (QSAR).

Toxicology 2023 August 8
Exposure to spray-formulated products for car cabin detailing is a potential risk for asthma induction. With a focus on the asthma-related endpoints sensitisation and irritation of the lungs, we performed an occupational risk assessment based on requirements in the EU Chemical Agents Directive. We identified 71 such spray products available in Denmark. We identified ingredient substances in safety data sheets and screened for harmonised classifications of respiratory sensitisation and airway irritation. For respiratory sensitisation, we also applied quantitative structure-activity relationship (QSAR). We modelled the exposure during 15minutes of work inside a car cabin, and determined the risk ratio of the products by further applying occupational exposure limits - mainly derived no-effect levels (DNELs) from the European Chemicals Agency (ECHA) set on respiratory irritation. Four substances had a harmonised classification for respiratory irritation (bronopol, 2-phenoxyethanol, 2-methoxypropanol, and butan-1-ol). Seven substances were positive in the QSAR model for respiratory sensitisation (monoethanolamine, bronopol, glycerol, methyl salicylate, benzoic acid, ammonium benzoate, and sodium benzoate). Two vinyl treatment products had a risk ratio >1 based on the level of sodium benzoate and its DNEL set on respiratory irritation. Two products had risk ratios of 0.69 and 0.73, respectively, based on 2-methyl-2H-isothiazol-3-one and its acute DNEL set on respiratory irritation. In conclusion, 10 substances that may pose a risk for asthma induction were identified in the products. Two of the 71 products had a risk ratio >1, meaning they may pose an asthma-induction risk in the modelled exposure scenario and using respiratory irritation DNELs from ECHA.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Group 7SearchHeart failure treatmentPapersTopicsCollectionsEffects of Sodium-Glucose Cotransporter 2 Inhibitors for the Treatment of Patients With Heart Failure Importance: Only 1 class of glucose-lowering agents-sodium-glucose cotransporter 2 (SGLT2) inhibitors-has been reported to decrease the risk of cardiovascular events primarily by reducingSeptember 1, 2017: JAMA CardiologyAssociations of albuminuria in patients with chronic heart failure: findings in the ALiskiren Observation of heart Failure Treatment study.CONCLUSIONS: Increased UACR is common in patients with heart failure, including non-diabetics. Urinary albumin creatininineJul, 2011: European Journal of Heart FailureRandomized Controlled TrialEffects of Liraglutide on Clinical Stability Among Patients With Advanced Heart Failure and Reduced Ejection Fraction: A Randomized Clinical Trial.Review

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app