We have located links that may give you full text access.
Accuracy of a Smartphone Software Application Compared With a Handheld Goniometer for Measuring Shoulder Range of Motion in Asymptomatic Adults.
Orthopaedic Journal of Sports Medicine 2023 July
BACKGROUND: Typically, shoulder range of motion (ROM) measurements are performed in a clinic setting, where physicians, physical therapists (PTs), and occupational therapists make use of a goniometer.
PURPOSE: To determine the accuracy of a smartphone-based ROM software application (app) in assessing active shoulder ROM and compare the measurements with traditional goniometry as measured by a PT.
STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 2.
METHODS: This prospective, nonblinded study was conducted at a single institution with adult asymptomatic participants with full active ROM of both shoulders. Participants were enrolled between June 1 and 15, 2021. Each participant self-assessed their active shoulder ROM using the PeerWell smartphone app. A single PT concurrently measured each participant's active shoulder ROM using a handheld universal goniometer. Bilateral shoulder ROM (forward flexion, abduction [AB], external rotation, internal rotation [IR], and extension) was measured 2 times for each participant. Interrater reliability between the smartphone app and PT measurements as well as intrarater reliability for each method of measurement were assessed using the intraclass correlation coefficient (ICC), and limits of agreement were analyzed for the difference in measurement methods.
RESULTS: Data were analyzed for 60 shoulders (30 right, 30 left) from 30 participants (mean age, 31.4 ± 11.7 years; 73% female). The interrater reliability between the 2 methods was excellent for all movements (ICCs, 0.90-0.96). For all movements except shoulder AB, the mean difference in the measurements between the 2 methods was <1.3°; the mean difference in AB ROM was 2.08°. For all movements except IR, both PTs and the app showed excellent intrarater reliability (ICCs >0.90); for IR, good intrarater reliability (ICC ≥0.75) was observed.
CONCLUSION: The PeerWell smartphone app provided measurements comparable with manual measurements taken by a PT using a goniometer. These data provide evidence that the smartphone app is a reliable and valid tool for measuring shoulder ROM and show promise for measuring and monitoring patient ROM remotely.
PURPOSE: To determine the accuracy of a smartphone-based ROM software application (app) in assessing active shoulder ROM and compare the measurements with traditional goniometry as measured by a PT.
STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 2.
METHODS: This prospective, nonblinded study was conducted at a single institution with adult asymptomatic participants with full active ROM of both shoulders. Participants were enrolled between June 1 and 15, 2021. Each participant self-assessed their active shoulder ROM using the PeerWell smartphone app. A single PT concurrently measured each participant's active shoulder ROM using a handheld universal goniometer. Bilateral shoulder ROM (forward flexion, abduction [AB], external rotation, internal rotation [IR], and extension) was measured 2 times for each participant. Interrater reliability between the smartphone app and PT measurements as well as intrarater reliability for each method of measurement were assessed using the intraclass correlation coefficient (ICC), and limits of agreement were analyzed for the difference in measurement methods.
RESULTS: Data were analyzed for 60 shoulders (30 right, 30 left) from 30 participants (mean age, 31.4 ± 11.7 years; 73% female). The interrater reliability between the 2 methods was excellent for all movements (ICCs, 0.90-0.96). For all movements except shoulder AB, the mean difference in the measurements between the 2 methods was <1.3°; the mean difference in AB ROM was 2.08°. For all movements except IR, both PTs and the app showed excellent intrarater reliability (ICCs >0.90); for IR, good intrarater reliability (ICC ≥0.75) was observed.
CONCLUSION: The PeerWell smartphone app provided measurements comparable with manual measurements taken by a PT using a goniometer. These data provide evidence that the smartphone app is a reliable and valid tool for measuring shoulder ROM and show promise for measuring and monitoring patient ROM remotely.
Full text links
Trending Papers
Monitoring Macro- and Microcirculation in the Critically Ill: A Narrative Review.Avicenna Journal of Medicine 2023 July
Euglycemic Ketoacidosis in Two Patients Without Diabetes After Introduction of Sodium-Glucose Cotransporter 2 Inhibitor for Heart Failure With Reduced Ejection Fraction.Diabetes Care 2023 November 22
ASA Consensus-based Guidance on Preoperative Management of Patients on Glucagon-like Peptide-1 Receptor Agonists.Anesthesiology 2023 November 21
Tranexamic Acid for Traumatic Injury in the Emergency Setting: A Systematic Review and Bias-Adjusted Meta-Analysis of Randomized Controlled Trials.Annals of Emergency Medicine 2023 November 22
Association between postinduction hypotension and postoperative mortality: a single-centre retrospective cohort study.Canadian Journal of Anaesthesia 2023 November 22
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app