We have located links that may give you full text access.
Dry suction water seal system for management of pericardial fluid during epicardial ablation.
Journal of Cardiovascular Electrophysiology 2023 August 2
INTRODUCTION: Epicardial ablation is an important approach in the management of patients with complex ventricular arrhythmias. Irrigated ablation catheters present a challenge in this potential space due to fluid accumulation that can cause hemodynamic compromise, requiring frequent manual fluid aspiration. In this series, we report our initial experience with the use of a dry suction water seal system for pericardial fluid management during epicardial ablation.
METHODS: Consecutive patients undergoing epicardial ventricular tachycardia (VT) ablation at a single center were included. All patients underwent epicardial access via a subxiphoid approach with a single operator. A deflectable sheath was advanced into the pericardial space, and the side port was attached to a dry suction water seal system attached to wall suction at -20 mmHg. Procedural information including patient characteristics, outcomes, and adverse events. After a period of initial experience, pericardial fluid infusion and aspiration volumes were recorded.
RESULTS: Eleven patients were included in this series. All patients underwent epicardial ablation with complete success achieved in 8 of the 11 patients and partial success in the remaining patients. Pericardial fluid intake ranging from 485 to 3050 mL with aspiration of 350-3050 mL using the dry suction water seal system. No adverse events occurred.
CONCLUSION: Dry suction water seal drainage systems can provide a safe strategy for efficient pericardial fluid management during epicardial VT ablation, potentially shortening procedure duration.
METHODS: Consecutive patients undergoing epicardial ventricular tachycardia (VT) ablation at a single center were included. All patients underwent epicardial access via a subxiphoid approach with a single operator. A deflectable sheath was advanced into the pericardial space, and the side port was attached to a dry suction water seal system attached to wall suction at -20 mmHg. Procedural information including patient characteristics, outcomes, and adverse events. After a period of initial experience, pericardial fluid infusion and aspiration volumes were recorded.
RESULTS: Eleven patients were included in this series. All patients underwent epicardial ablation with complete success achieved in 8 of the 11 patients and partial success in the remaining patients. Pericardial fluid intake ranging from 485 to 3050 mL with aspiration of 350-3050 mL using the dry suction water seal system. No adverse events occurred.
CONCLUSION: Dry suction water seal drainage systems can provide a safe strategy for efficient pericardial fluid management during epicardial VT ablation, potentially shortening procedure duration.
Full text links
Related Resources
Trending Papers
2024 AHA/ACC/ACS/ASNC/HRS/SCA/SCCT/SCMR/SVM Guideline for Perioperative Cardiovascular Management for Noncardiac Surgery: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines.Circulation 2024 September 24
Pathophysiology and Treatment of Prediabetes and Type 2 Diabetes in Youth.Diabetes Care 2024 September 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app