Diagnostic accuracy of a simple qualitative ultrasound assessment for the diagnosis of empty stomach in the adult: A supplementary analysis of a prospective observer-blind randomized crossover study.

BACKGROUND: It has been reported that qualitative ultrasound assessment performed in the semi-upright position had high sensitivity to detect gastric fluid volume >1.5 mL.kg-1 . Nevertheless, the diagnostic accuracy of qualitative assessment for the diagnosis of empty stomach (fluid volume <0.8 mL.kg-1 ) has not been assessed. We aimed to assess the diagnostic accuracy of simple qualitative ultrasound assessment with and without head-of-bed elevation to 45° for the diagnosis of an empty stomach. We also aimed to determine the diagnostic accuracy of a composite ultrasound scale and clinical algorithm.

METHODS: We performed a supplementary analysis of a prospective observer-blind randomized crossover trial in which adult fasting volunteers attended two distinct sessions, with the head-of-bed angled either at 0° or 45°, in a randomized order. Three tests were performed within each session, each corresponding to a different (either 0, 50, 100, 150 or 200 mL) and randomized volume of water; the same volumes were ingested in both sessions, in a randomized order. Ultrasounds were performed 3 min after water ingestion, blindly to the volume ingested.

RESULTS: We included 20 volunteers in whom 120 measurements were analyzed. The sensitivity and specificity of the qualitative assessment in the semirecumbent position were 93% (95% CI: 68-100) and 89% (95% CI: 76-96), respectively. The composite scale and clinical algorithm did not have better diagnostic accuracy than the qualitative assessment performed with head-of-bed elevation. Without head-of-bed elevation, the clinical algorithm had significantly higher specificity (98% [95% CI: 88-100]) than qualitative assessment (67% [95% CI: 51-80]; p < 0.05).

CONCLUSION: These results suggest that qualitative assessment in the semirecumbent position had high diagnostic accuracy for the diagnosis of fluid volume <0.8 mL.kg-1 ; this method can be used in clinical practice for reliable diagnosis of empty stomach.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Group 7SearchHeart failure treatmentPapersTopicsCollectionsEffects of Sodium-Glucose Cotransporter 2 Inhibitors for the Treatment of Patients With Heart Failure Importance: Only 1 class of glucose-lowering agents-sodium-glucose cotransporter 2 (SGLT2) inhibitors-has been reported to decrease the risk of cardiovascular events primarily by reducingSeptember 1, 2017: JAMA CardiologyAssociations of albuminuria in patients with chronic heart failure: findings in the ALiskiren Observation of heart Failure Treatment study.CONCLUSIONS: Increased UACR is common in patients with heart failure, including non-diabetics. Urinary albumin creatininineJul, 2011: European Journal of Heart FailureRandomized Controlled TrialEffects of Liraglutide on Clinical Stability Among Patients With Advanced Heart Failure and Reduced Ejection Fraction: A Randomized Clinical Trial.Review

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app