Non-anticoagulant factors affecting coagulation in the extracorporeal circulation circuit and the development of an individualized regional citrate anticoagulation protocol for hemodialysis: A real-world retrospective study.
OBJECTIVE: To investigate non-anticoagulant factors that affect blood coagulation in the extracorporeal circulation (ECC) circuit of regional citrate anticoagulation (RCA) protocol for hemodialysis (HD).
METHOD: The clinical characteristics of patients undergoing an individualized RCA protocol for HD between February 2021 and March 2022 were collected; Coagulation scores, pressures in various parts of the ECC circuit, the incidence of coagulation, and citrate concentrations in the ECC circuit during treatment were determined, and non-anticoagulant factors affecting coagulation in the ECC circuit were analyzed.
RESULT: The lowest clotting rate was 2.8% in patients with arteriovenous fistula in various vascular access. Patients on Fresenius dialysis had a lower rate of clotting in the cardiopulmonary bypass line than patients on other brands of dialyzer. Low-throughput dialyzers are less likely to clot than high-throughput dialyzers. There are significant differences in the incidence of coagulation among different nurses during citrate anticoagulant hemodialysis.
CONCLUSION: In the process of citrate anticoagulant hemodialysis, non-anticoagulant factors such as coagulation status, vascular access, dialyzer selection, and operator quality will affect the anticoagulant effect.
METHOD: The clinical characteristics of patients undergoing an individualized RCA protocol for HD between February 2021 and March 2022 were collected; Coagulation scores, pressures in various parts of the ECC circuit, the incidence of coagulation, and citrate concentrations in the ECC circuit during treatment were determined, and non-anticoagulant factors affecting coagulation in the ECC circuit were analyzed.
RESULT: The lowest clotting rate was 2.8% in patients with arteriovenous fistula in various vascular access. Patients on Fresenius dialysis had a lower rate of clotting in the cardiopulmonary bypass line than patients on other brands of dialyzer. Low-throughput dialyzers are less likely to clot than high-throughput dialyzers. There are significant differences in the incidence of coagulation among different nurses during citrate anticoagulant hemodialysis.
CONCLUSION: In the process of citrate anticoagulant hemodialysis, non-anticoagulant factors such as coagulation status, vascular access, dialyzer selection, and operator quality will affect the anticoagulant effect.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app