We have located links that may give you full text access.
Vasoactive Inotropic Score compared to the sequential organ failure assessment cardiovascular score in intensive care.
Acta Anaesthesiologica Scandinavica 2023 October
BACKGROUND: The cardiovascular component of the sequential organ failure assessment (cvSOFA) score may be outdated because of changes in intensive care. Vasoactive Inotropic Score (VIS) represents the weighted sum of vasoactive and inotropic drugs. We investigated the association of VIS with mortality in the general intensive care unit (ICU) population and studied whether replacing cvSOFA with a VIS-based score improves the accuracy of the SOFA score as a predictor of mortality.
METHODS: We studied the association of VIS during the first 24 h after ICU admission with 30-day mortality in a retrospective study on adult medical and non-cardiac emergency surgical patients admitted to Kuopio University Hospital ICU, Finland, in 2013-2019. We determined the area under the receiver operating characteristic curve (AUROC) for the original SOFA and for SOFAVISmax , where cvSOFA was replaced with maximum VIS (VISmax ) categories.
RESULTS: Of 8079 patients, 1107 (13%) died within 30 days. Mortality increased with increasing VISmax . AUROC was 0.813 (95% confidence interval [CI], 0.800-0.825) for original SOFA and 0.822 (95% CI: 0.810-0.834) for SOFAVISmax , p < .001.
CONCLUSION: Mortality increased consistently with increasing VISmax . Replacing cvSOFA with VISmax improved the predictive accuracy of the SOFA score.
METHODS: We studied the association of VIS during the first 24 h after ICU admission with 30-day mortality in a retrospective study on adult medical and non-cardiac emergency surgical patients admitted to Kuopio University Hospital ICU, Finland, in 2013-2019. We determined the area under the receiver operating characteristic curve (AUROC) for the original SOFA and for SOFAVISmax , where cvSOFA was replaced with maximum VIS (VISmax ) categories.
RESULTS: Of 8079 patients, 1107 (13%) died within 30 days. Mortality increased with increasing VISmax . AUROC was 0.813 (95% confidence interval [CI], 0.800-0.825) for original SOFA and 0.822 (95% CI: 0.810-0.834) for SOFAVISmax , p < .001.
CONCLUSION: Mortality increased consistently with increasing VISmax . Replacing cvSOFA with VISmax improved the predictive accuracy of the SOFA score.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app