Consecutive Experience with Left Bundle Branch Area Pacing in a High-Volume Australian Centre.
Heart, Lung & Circulation 2023 May 25
INTRODUCTION: Left-bundle branch area pacing (LBBAP) is a relatively new technique for conduction system pacing. Australian safety and efficacy data is currently lacking. We aim to evaluate the learning curve, medium-term safety, and lead performance in a high-volume Australian setting.
METHODS: We performed a retrospective cohort study of 200 consecutive LBBAP procedures performed by a single operator at two centres between January 2019 and May 2020. Left bundle branch area pacing was performed predominantly via left subclavian access using a 69 cm Medtronic SelectSecure 3830 pacing lead and a preformed non-steerable C315-His sheath. Procedural success was defined as evidence of left septal or left bundle branch area capture as evidenced by a right bundle branch block-like paced morphology. Procedural characteristics, and follow-up (including lead performance) data were collected. Procedural efficiency over time, as well as safety data, were collected.
RESULTS: Median age was 78.26 years (interquartile range [IQR] 71-85), 37% were female. Atrial fibrillation was present in 22%. The left ventricular ejection fraction <50% in 24%, atrioventricular (AV) block was present in 43.5%, left bundle branch block in 22.5% and right bundle branch block in 24.5%. Acute procedural success was 91.5%. Implant threshold was 0.6V @ 0.5 ms, and 0.75V @ 0.5 ms at 11.9 months of follow-up. The QRS was significant reduced (baseline 134 ms vs implant 114 ms, p<0.001) There was a reduction in procedural time and X-ray dose over the course of the study. There were no complications specific to LBBAP.
CONCLUSION: LBBAP appears to be a safe and effective pacing strategy. The QRS duration was significantly reduced compared to baseline. There appears to be an early learning curve with LBBAP.
METHODS: We performed a retrospective cohort study of 200 consecutive LBBAP procedures performed by a single operator at two centres between January 2019 and May 2020. Left bundle branch area pacing was performed predominantly via left subclavian access using a 69 cm Medtronic SelectSecure 3830 pacing lead and a preformed non-steerable C315-His sheath. Procedural success was defined as evidence of left septal or left bundle branch area capture as evidenced by a right bundle branch block-like paced morphology. Procedural characteristics, and follow-up (including lead performance) data were collected. Procedural efficiency over time, as well as safety data, were collected.
RESULTS: Median age was 78.26 years (interquartile range [IQR] 71-85), 37% were female. Atrial fibrillation was present in 22%. The left ventricular ejection fraction <50% in 24%, atrioventricular (AV) block was present in 43.5%, left bundle branch block in 22.5% and right bundle branch block in 24.5%. Acute procedural success was 91.5%. Implant threshold was 0.6V @ 0.5 ms, and 0.75V @ 0.5 ms at 11.9 months of follow-up. The QRS was significant reduced (baseline 134 ms vs implant 114 ms, p<0.001) There was a reduction in procedural time and X-ray dose over the course of the study. There were no complications specific to LBBAP.
CONCLUSION: LBBAP appears to be a safe and effective pacing strategy. The QRS duration was significantly reduced compared to baseline. There appears to be an early learning curve with LBBAP.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app