We have located links that may give you full text access.
JOURNAL ARTICLE
RANDOMIZED CONTROLLED TRIAL
Prediction of Implantable Collamer Lens Vault Based on Preoperative Biometric Factors and Lens Parameters.
Journal of Refractive Surgery 2023 May
PURPOSE: To establish and validate the accuracy of implantable collamer lens (ICL) vault size prediction formula based on preoperative biometric factors and lens parameters.
METHODS: This study included 300 patients (300 eyes) with Visian ICL V4c (STAAR Surgical) implantation. They were randomly divided into the formula establishment group and formula validation group. Anterior segment measurements, ICL V4c size and power, and vault 1 week postoperatively were collected from all patients. Multiple linear regression analysis was performed to establish the prediction formula. Mean absolute error (MAE), median absolute error (MedAE), root mean square error (RMSE), and Bland-Altman diagrams were used to evaluate the prediction formula.
RESULTS: Anterior chamber depth (ACD) had the greatest influence on vault 1 week after ICL V4c implantation, followed by ICL V4c size and angle-to-angle distance (ATA). The prediction formula was obtained according to the partial regression coefficient, which was vault (mm) = -1.279 + 0.291 × ACD (mm) + 0.210 × ICL V4c size (mm) - 0.144 × ATA (mm) ( R 2 = 0.661). In the formula validation group, the mean predictive vault, MAE, MedAE, and RMSE were 628.10, 135.09, 130.42, and 150.46 µm, respectively. The Bland-Altman diagram showed the predictive vault was in good agreement with the actual vault.
CONCLUSIONS: A novel ICL V4c vault prediction formula was developed and shown to be an effective method for predicting the vault to reduce surgical complications. [ J Refract Surg . 2023;39(5):332-339.] .
METHODS: This study included 300 patients (300 eyes) with Visian ICL V4c (STAAR Surgical) implantation. They were randomly divided into the formula establishment group and formula validation group. Anterior segment measurements, ICL V4c size and power, and vault 1 week postoperatively were collected from all patients. Multiple linear regression analysis was performed to establish the prediction formula. Mean absolute error (MAE), median absolute error (MedAE), root mean square error (RMSE), and Bland-Altman diagrams were used to evaluate the prediction formula.
RESULTS: Anterior chamber depth (ACD) had the greatest influence on vault 1 week after ICL V4c implantation, followed by ICL V4c size and angle-to-angle distance (ATA). The prediction formula was obtained according to the partial regression coefficient, which was vault (mm) = -1.279 + 0.291 × ACD (mm) + 0.210 × ICL V4c size (mm) - 0.144 × ATA (mm) ( R 2 = 0.661). In the formula validation group, the mean predictive vault, MAE, MedAE, and RMSE were 628.10, 135.09, 130.42, and 150.46 µm, respectively. The Bland-Altman diagram showed the predictive vault was in good agreement with the actual vault.
CONCLUSIONS: A novel ICL V4c vault prediction formula was developed and shown to be an effective method for predicting the vault to reduce surgical complications. [ J Refract Surg . 2023;39(5):332-339.] .
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app