MRI tagging of colonic chyme mixing in healthy subjects: Inter-observer variability and reliability of the measurement with time.

BACKGROUND: Magnetic resonance imaging (MRI) tagging techniques have been applied to the GI tract to assess bowel contractions and content mixing. We aimed to evaluate the dependence of a tagging measurement (for assessing chyme mixing) on inter-observer variability in both the ascending colon (AC) and descending colon (DC) and to investigate the temporal variation and hence reliability of the colonic tagging technique by acquiring multiple measurements over time on healthy participants.

METHODS: Two independent datasets of healthy adults were used for the retrospective inter-observer variability (Study 1: 13 datasets and Study 2: 31 datasets), and ten participants were scanned for the prospective temporal variation study following a 1 L mannitol oral preparation. All colonic tagging data were acquired on 3 T MRI scanners. The mean and the standard deviation (SD) maps were generated pixel-by-pixel using custom-written software in MATLAB. The colonic regions of interest were defined using MIPAV software. Bland-Altman plots and scatter plots were used for the inter-observer variability. The mean and SD of all repeated measures for each subject were calculated along with a one-way ANOVA to test for variations with time.

RESULTS: Scatter plots and Bland-Altman plots showed a large range of data with low variation and small limits of agreements (<5% CoV). The intraclass correlation coefficient of inter-rater reliability was excellent and 0.97 or above for the AC and DC measurements for both datasets. The temporal variation study shows that there was no significant difference found between the multiple measures with time (p = 0.53, one-way repeated measures ANOVA test).

CONCLUSIONS: MRI tagging technique can provide an assessment of colonic chyme mixing. The inter-observer study data showed high inter-rater agreement. The temporal variation study showed some individual variations with time suggesting multiple measurements may be needed to increase accuracy.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app