We have located links that may give you full text access.
Journal Article
Meta-Analysis
Review
Systematic Review
Robot-assisted vs. manually guided stereoelectroencephalography for refractory epilepsy: a systematic review and meta-analysis.
Neurosurgical Review 2023 May 3
Robotic assistance has improved electrode implantation precision in stereoelectroencephalography (SEEG) for refractory epilepsy patients. We sought to assess the relative safety of the robotic-assisted (RA) procedure compared to the traditional hand-guided one. A systematic search on PubMed, Web of Science, Embase, and Cochrane was performed for studies directly comparing robot-assisted vs. manually guided SEEG to treat refractory epilepsy. The primary outcomes included target point error (TPE), entry point error (EPE), time of implantation of each electrode, operative time, postoperative intracranial hemorrhage, infection, and neurologic deficit. We included 427 patients from 11 studies, of whom 232 (54.3%) underwent robot-assisted surgery and 196 (45.7%) underwent manually guided surgery. The primary endpoint, TPE, was not statistically significant (MD 0.04 mm; 95% CI - 0.21, - 0.29; p = 0.76). Nonetheless, EPE was significantly lower in the intervention group (MD - 0.57 mm; 95% CI - 1.08; - 0.06; p = 0.03). Total operative time was significantly lower in the RA group (MD - 23.66 min; 95% CI - 32.01, - 15.31; p < 0.00001), as well as the individual time of implantation of each electrode (MD - 3.35 min; 95% CI - 3.68, - 3.03; p < 0.00001). Postoperative intracranial hemorrhage did not differ between groups: robotic (9/145; 6.2%) vs. manual (8/139; 5.7%) (RR 0.97; 95% CI 0.40-2.34; p = 0.94). There was no statistically relevant difference in infection (p = 0.4) and postoperative neurological deficit (p = 0.47) incidence between the two groups. In this analysis, there is a potential relevance in the RA procedure when comparing the traditional one, since operative time, time of implantation of each electrode, and EPE were significantly lower in the robotic group. More research is needed to corroborate the superiority of this novel technique.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app