High-Speed Onsite Deep-Learning Based FFR-CT Algorithm: Evaluation Using Invasive Angiography as Reference Standard.
AJR. American Journal of Roentgenology 2023 May 4
Background: Estimation of fractional flow reserve (FFR) from coronary CTA (FFR-CT) is an established method to assess coronary lesions' hemodynamic significance. However, clinical implementation has progressed slowly, partly related to offsite data transfer with long turnaround times while awaiting results. Objectives: We aimed to evaluate the diagnostic performance of FFR-CT computed onsite with a high-speed deep-learning based algorithm, using invasive hemodynamic indices as reference standard. Methods: This retrospective study included 59 patients (46 men, 13 women; mean age 66.5±10.2 years) who underwent coronary CTA (including calcium scoring) followed within 90 days by invasive angiography with invasive FFR and/or instantaneous wave-free ratio (iwFR) measurements from December 2014 to October 2021. Coronary artery lesions were considered to show hemodynamically significant stenosis in presence of invasive FFR ≤0.80 and/or iwFR ≤0.89. A single cardiologist evaluated CTA images using an onsite deep-learning based semiautomated algorithm employing a 3D computational flow dynamics model to determine FFR-CT for coronary artery lesions detected by invasive angiography. Time for FFR-CT analysis was recorded. FFR-CT analysis was repeated by the same cardiologist in 26 randomly selected examinations, and by a different cardiologist in 45 randomly selected examinations. Diagnostic performance and agreement were assessed. Results: Invasive angiography identified 74 lesions. FFR-CT and invasive FFR showed strong correlation (r=0.81), and, in Bland-Altman analysis, showed bias of 0.01 and 95% limits of agreement of -0.13 to +0.15. FFR-CT had AUC for hemodynamically significant stenosis of 0.975. At cutoff of ≤0.80, FFR-CT had accuracy of 95.9%, sensitivity of 93.5%, and specificity of 97.7%. In 39 lesions with severe calcifications (≥400 Agatston units), FFR-CT had AUC of 0.991, with cutoff of ≤0.80 yielding sensitivity of 94.7%, specificity of 95.0%, and accuracy of 94.9%. Mean analysis time per patient was 7 minutes 54 seconds. Interobserver and intraobserver agreement were good-to-excellent (intraclass correlation coefficient, 0.944 and 0.854; bias -0.01 and -0.01; 95% limits of agreement, -0.08 to +0.07, and -0.12 and +0.10, respectively). Conclusion: A high-speed onsite deep-learning based FFR-CT algorithm showed excellent diagnostic performance for hemodynamically significant stenosis, with high reproducibility. Clinical Impact: The algorithm should facilitate the FFR-CT technology's implementation into routine clinical practice.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app