Effect of high-intensity statin therapy on atherosclerosis (IBIS-4): Manual versus automated methods of IVUS analysis.
AIMS: Standard manual analysis of IVUS to study the impact of anti-atherosclerotic therapies on the coronary vessel wall is done by a core laboratory (CL), the ground truth (GT). Automatic segmentation of IVUS with a machine learning (ML) algorithm has the potential to replace manual readings with an unbiased and reproducible method. The aim is to determine if results from a CL can be replicated with ML methods.
METHODS: This is a post-hoc, comparative analysis of the IBIS-4 (Integrated Biomarkers and Imaging Study-4) study (NCT00962416). The GT baseline and 13-month follow-up measurements of lumen and vessel area and percent atheroma volume (PAV) after statin induction were repeated by the ML algorithm.
RESULTS: The primary endpoint was change in PAV. PAV as measured by GT was 43.95 % at baseline and 43.02 % at follow-up with a change of -0.90 % (p = 0.007) while the ML algorithm measured 43.69 % and 42.41 % for baseline and follow-up, respectively, with a change of -1.28 % (p < 0.001). Along the most diseased 10 mm segments, GT-PAV was 52.31 % at baseline and 49.42 % at follow-up, with a change of -2.94 % (p < 0.001). The same segments measured by the ML algorithm resulted in PAV of 51.55 % at baseline and 47.81 % at follow-up with a change of -3.74 % (p < 0.001).
CONCLUSIONS: PAV, the most used endpoint in clinical trials, analyzed by the CL is closely replicated by the ML algorithm. ML automatic segmentation of lumen, vessel and plaque effectively reproduces GT and may be used in future clinical trials as the standard.
METHODS: This is a post-hoc, comparative analysis of the IBIS-4 (Integrated Biomarkers and Imaging Study-4) study (NCT00962416). The GT baseline and 13-month follow-up measurements of lumen and vessel area and percent atheroma volume (PAV) after statin induction were repeated by the ML algorithm.
RESULTS: The primary endpoint was change in PAV. PAV as measured by GT was 43.95 % at baseline and 43.02 % at follow-up with a change of -0.90 % (p = 0.007) while the ML algorithm measured 43.69 % and 42.41 % for baseline and follow-up, respectively, with a change of -1.28 % (p < 0.001). Along the most diseased 10 mm segments, GT-PAV was 52.31 % at baseline and 49.42 % at follow-up, with a change of -2.94 % (p < 0.001). The same segments measured by the ML algorithm resulted in PAV of 51.55 % at baseline and 47.81 % at follow-up with a change of -3.74 % (p < 0.001).
CONCLUSIONS: PAV, the most used endpoint in clinical trials, analyzed by the CL is closely replicated by the ML algorithm. ML automatic segmentation of lumen, vessel and plaque effectively reproduces GT and may be used in future clinical trials as the standard.
Full text links
Related Resources
Trending Papers
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app