Myocardial Scar Detection Using High-Resolution Free-Breathing 3D Dark-Blood and Standard Breath-Holding 2D Bright-Blood Late Gadolinium Enhancement MRI: A Comparison of Observer Confidence.
Topics in Magnetic Resonance Imaging : TMRI 2023 April 13
OBJECTIVE: To compare observer confidence for myocardial scar detection using 3 different late gadolinium enhancement (LGE) data sets by 2 observers with different levels of experience.
MATERIALS AND METHODS: Forty-one consecutive patients, who were referred for 3D dark-blood LGE MRI before implantable cardioverter-defibrillator implantation or ablation therapy and who underwent 2D bright-blood LGE MRI within a time frame of 3 months, were prospectively included. From all 3D dark-blood LGE data sets, a stack of 2D short-axis slices was reconstructed. All acquired LGE data sets were anonymized and randomized and evaluated by 2 independent observers with different levels of experience in cardiovascular imaging (beginner and expert). Confidence in detection of ischemic scar, nonischemic scar, papillary muscle scar, and right ventricular scar for each LGE data set was scored using a using a 3-point Likert scale (1 = low, 2 = medium, or 3 = high). Observer confidence scores were compared using the Friedman omnibus test and Wilcoxon signed-rank post hoc test.
RESULTS: For the beginner observer, a significant difference in confidence regarding ischemic scar detection was observed in favor of reconstructed 2D dark-blood LGE compared with standard 2D bright-blood LGE (p = 0.030) while for the expert observer, no significant difference was found (p = 0.166). Similarly, for right ventricular scar detection, a significant difference in confidence was observed in favor of reconstructed 2D dark-blood LGE compared with standard 2D bright-blood LGE (p = 0.006) while for the expert observer, no significant difference was found (p = 0.662). Although not significantly different for other areas of interest, 3D dark-blood LGE and its derived 2D dark-blood LGE data set showed a tendency to score higher for all areas of interest at both experience levels.
CONCLUSIONS: The combination of dark-blood LGE contrast and high isotropic voxels may contribute to increased observer confidence in myocardial scar detection, independent of observer's experience level but in particular for beginner observers.
MATERIALS AND METHODS: Forty-one consecutive patients, who were referred for 3D dark-blood LGE MRI before implantable cardioverter-defibrillator implantation or ablation therapy and who underwent 2D bright-blood LGE MRI within a time frame of 3 months, were prospectively included. From all 3D dark-blood LGE data sets, a stack of 2D short-axis slices was reconstructed. All acquired LGE data sets were anonymized and randomized and evaluated by 2 independent observers with different levels of experience in cardiovascular imaging (beginner and expert). Confidence in detection of ischemic scar, nonischemic scar, papillary muscle scar, and right ventricular scar for each LGE data set was scored using a using a 3-point Likert scale (1 = low, 2 = medium, or 3 = high). Observer confidence scores were compared using the Friedman omnibus test and Wilcoxon signed-rank post hoc test.
RESULTS: For the beginner observer, a significant difference in confidence regarding ischemic scar detection was observed in favor of reconstructed 2D dark-blood LGE compared with standard 2D bright-blood LGE (p = 0.030) while for the expert observer, no significant difference was found (p = 0.166). Similarly, for right ventricular scar detection, a significant difference in confidence was observed in favor of reconstructed 2D dark-blood LGE compared with standard 2D bright-blood LGE (p = 0.006) while for the expert observer, no significant difference was found (p = 0.662). Although not significantly different for other areas of interest, 3D dark-blood LGE and its derived 2D dark-blood LGE data set showed a tendency to score higher for all areas of interest at both experience levels.
CONCLUSIONS: The combination of dark-blood LGE contrast and high isotropic voxels may contribute to increased observer confidence in myocardial scar detection, independent of observer's experience level but in particular for beginner observers.
Full text links
Related Resources
Trending Papers
Updated evidence on cardiovascular and renal effects of GLP-1 receptor agonists and combination therapy with SGLT2 inhibitors and finerenone: a narrative review and perspectives.Cardiovascular Diabetology 2024 November 15
Guidelines for the Prevention, Diagnosis, and Management of Urinary Tract Infections in Pediatrics and Adults: A WikiGuidelines Group Consensus Statement.JAMA Network Open 2024 November 4
Autoantibodies in neuromuscular disorders: a review of their utility in clinical practice.Frontiers in Neurology 2024
Methods for determining optimal positive end-expiratory pressure in patients undergoing invasive mechanical ventilation: a scoping review.Canadian Journal of Anaesthesia 2024 November 20
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app