Add like
Add dislike
Add to saved papers

Capillary Flow-Driven Microfluidics Combined with a Paper Device for Fast User-Friendly Detection of Heavy Metals in Water.

Analytical Chemistry 2023 March 24
Human exposure to heavy metals is a concerning global problem because of its detrimental effect on our health and ecosystem. Assessing the levels of these metals is cost- and labor-intensive and nonuser friendly because current analysis approaches typically rely on heavy instrumentations like inductively coupled plasma-mass spectrometry, which is only possible in centralized labs. Hence, simple economical detection methods are in high demand in developing countries and areas with insufficient infrastructure, professional experts, and appropriate environmental treatment. Several microfluidic paper-based analytical devices have been reported as promising alternatives to conventional testing methods for on-site heavy metal detection. Paper-based microfluidics are advantageous because of their simple fabrication, biodegradability, low cost, and ability to operate without pumps. However, typical assay times for current platforms are slow, and they typically rely on pipetting a fixed volume into the assay cards. This adds complexity in actual field scenarios. Here, we report a novel, inexpensive, and straightforward capillary-driven microfluidic device combined with paper for rapid and user-friendly detection of Ni(II), Cu(II), and Fe(III) in water. A colorimetric approach was adopted to quantify these metals. The device was able to produce a homogeneous color signal within 8 s of sample insertion. The limit of detection and limit of quantification were calculated to be 2 and 6.67 ppm for nickel, 0.3 and 1 ppm for Cu, and 1.1 and 3.67 ppm for Fe, respectively. The majority (>90%) of the collected samples showed recovery in the 80-110% range with acceptable accuracy and precision (<15% RSD) for a colorimetric device. This technique can be beneficial for rapidly assessing heavy metal exposure in drinking and surface water at drastically reduced assay time and is the first example of capillary flow-driven microfluidic devices as a transport medium for heavy metal detection.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app