Efficiency evaluation of a SARS-CoV-2 diagnostic strategy combining high throughput quantitative antigen immunoassay and real time PCR.
Clinical Chemistry and Laboratory Medicine : CCLM 2023 March 23
OBJECTIVES: Laboratory testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has played an important role in the effort to prevent and contain local outbreaks. The aim of this study was to assess the diagnostic accuracy of a new fully automated SARS-CoV-2 laboratory-based antigen assay (CoV2Ag) and to explore the efficiency of a diagnostic algorithm combining antigen and conventional high-throughput molecular assays to address potential future challenges of the SARS-CoV-2 pandemic.
METHODS: One thousand two hundred and twenty four consecutive nasopharyngeal swabs were tested using RT-PCR and CoV2Ag assay.
RESULTS: The overall sensitivity and specificity of CoV2Ag were 79.1 and 97.8%, respectively. When the analysis was restricted to cases with Ct values ≤30, the sensitivity of the assay improved to 98.1%. Acceptable sensitivity was found when the analysis was limited to patients presenting within one or two to four days of symptom onset (80.5 and 84.8%, respectively). A retrospective analysis of the use of a two-step diagnostic approach combining the CoV2Ag assay and RT-PCR during an acute pandemic phase of 97 days showed a potential reduction in the number of RT-PCR tests by 36.1%, corresponding to savings in reagent costs and technician workload of approximately €8,000 and 10.5 h per day, respectively.
CONCLUSIONS: Our data show that the proposed algorithm represents a valid alternative diagnostic approach to increase testing efficiency during future pandemic phases with high positivity rates (>20%) and elevated numbers of RT-PCR test requests.
METHODS: One thousand two hundred and twenty four consecutive nasopharyngeal swabs were tested using RT-PCR and CoV2Ag assay.
RESULTS: The overall sensitivity and specificity of CoV2Ag were 79.1 and 97.8%, respectively. When the analysis was restricted to cases with Ct values ≤30, the sensitivity of the assay improved to 98.1%. Acceptable sensitivity was found when the analysis was limited to patients presenting within one or two to four days of symptom onset (80.5 and 84.8%, respectively). A retrospective analysis of the use of a two-step diagnostic approach combining the CoV2Ag assay and RT-PCR during an acute pandemic phase of 97 days showed a potential reduction in the number of RT-PCR tests by 36.1%, corresponding to savings in reagent costs and technician workload of approximately €8,000 and 10.5 h per day, respectively.
CONCLUSIONS: Our data show that the proposed algorithm represents a valid alternative diagnostic approach to increase testing efficiency during future pandemic phases with high positivity rates (>20%) and elevated numbers of RT-PCR test requests.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app