Pacing manouvers from the aortic cusps: a useful technique during ablation of focal arrhythmias arising from the aortic root.
Pacing and Clinical Electrophysiology : PACE 2023 March 22
BACKGROUND: The ablation of arrhythmias arising near the His-bundle region in the non-coronary aortic cusp (NCAC) is challenging. Among the aortic sinuses of Valsalva, the NCAC is located between the right atrium and the left atrium. For this reason, pacing from the NCAC should result in atrial capture while pacing from the right and left coronary cusps (LCC) may result in ventricular capture. The objective of this study is to prove that atrial capture during pacing from the sinuses of Valsalva may be used to confirm a correct position in the non-coronary cusp.
METHODS: A total of 30 patients with structurally normal heart undergoing left sided ablation procedures, underwent electrophysiological study of the aortic cusps. Each of the aortic valve cusps was paced with increasing outputs and analyzed offline to determine their unique electrocardiographic characteristics.
RESULTS: In the NCAC, we obtained an atrial capture in 29 out of 30 patients (96,6%). The atrial capture was highly specific for a position in the NCAC (p<0.001). The median output required to capture from the cusp was 10 mA (range 5-25 mA) at a pulse width of 2 ms. In the right coronary cusp (RCC) and LCC, we obtained ventricular capture in all patients (100%). The median output required to capture from the cusp was 10 mA (range 10-25 mA) in RCC and 25 mA (range 10-25 mA) in LCC at a pulse width of 2 ms.
CONCLUSIONS: Atrial capture during a pacemapping from the aortic cusps can be considered proof of a correct position in NCAC. This article is protected by copyright. All rights reserved.
METHODS: A total of 30 patients with structurally normal heart undergoing left sided ablation procedures, underwent electrophysiological study of the aortic cusps. Each of the aortic valve cusps was paced with increasing outputs and analyzed offline to determine their unique electrocardiographic characteristics.
RESULTS: In the NCAC, we obtained an atrial capture in 29 out of 30 patients (96,6%). The atrial capture was highly specific for a position in the NCAC (p<0.001). The median output required to capture from the cusp was 10 mA (range 5-25 mA) at a pulse width of 2 ms. In the right coronary cusp (RCC) and LCC, we obtained ventricular capture in all patients (100%). The median output required to capture from the cusp was 10 mA (range 10-25 mA) in RCC and 25 mA (range 10-25 mA) in LCC at a pulse width of 2 ms.
CONCLUSIONS: Atrial capture during a pacemapping from the aortic cusps can be considered proof of a correct position in NCAC. This article is protected by copyright. All rights reserved.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app