Anatomical landmarks for localisation of the anterior ethmoidal artery: a combined radiological and cadaveric (endoscopic) study.
PURPOSE: The anterior ethmoidal artery is a major surgical landmark that is susceptible to iatrogenic injury during surgery of the anterior ethmoidal sinus, frontal sinus, and skull base. The present study aimed to define the location of the anterior ethmoidal artery in relation to specific anatomical landmarks using radiological imaging and endoscopic dissection.
METHODS: Eighty-six anterior ethmoidal arteries were assessed using computed tomography scans (bilateral analyses) and forty anterior ethmoidal arteries were assessed using cadaveric specimens (bilateral analyses). The skull base, anterior nasal spine, anterior axilla of the middle turbinate, and nasal axilla were morphometrically analysed to determine their reliability as anterior ethmoidal artery landmarks.
RESULTS: Distances to the skull base, anterior nasal spine, and nasal axilla displayed statistically significant differences between sexes and sides (p < 0.05). All landmarks demonstrated excellent reliability as anatomical landmarks for the localisation of the anterior ethmoidal artery, radiologically and endoscopically (ICC values ranged from 0.94 to 0.99).
CONCLUSION: The middle turbinate axilla was the most reliable landmark, due to the lack of statistically significant differences according to sex and laterality, and the high inter-rater agreement between measurements. Anatomical knowledge of variations and relationships observed in the present study can be applied to surgeries of the anterior ethmoidal sinus, frontal sinus, and skull base to improve localisation of the anterior ethmoidal artery, preoperatively and intraoperatively, and avoid iatrogenic injury of the vessel.
METHODS: Eighty-six anterior ethmoidal arteries were assessed using computed tomography scans (bilateral analyses) and forty anterior ethmoidal arteries were assessed using cadaveric specimens (bilateral analyses). The skull base, anterior nasal spine, anterior axilla of the middle turbinate, and nasal axilla were morphometrically analysed to determine their reliability as anterior ethmoidal artery landmarks.
RESULTS: Distances to the skull base, anterior nasal spine, and nasal axilla displayed statistically significant differences between sexes and sides (p < 0.05). All landmarks demonstrated excellent reliability as anatomical landmarks for the localisation of the anterior ethmoidal artery, radiologically and endoscopically (ICC values ranged from 0.94 to 0.99).
CONCLUSION: The middle turbinate axilla was the most reliable landmark, due to the lack of statistically significant differences according to sex and laterality, and the high inter-rater agreement between measurements. Anatomical knowledge of variations and relationships observed in the present study can be applied to surgeries of the anterior ethmoidal sinus, frontal sinus, and skull base to improve localisation of the anterior ethmoidal artery, preoperatively and intraoperatively, and avoid iatrogenic injury of the vessel.
Full text links
Trending Papers
2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines.Circulation 2023 November 31
How we approach titrating PEEP in patients with acute hypoxemic failure.Critical Care : the Official Journal of the Critical Care Forum 2023 October 32
ANCA-associated vasculitis - Treatment Standard.Nephrology, Dialysis, Transplantation 2023 November 9
The alternative renin-angiotensin system in critically ill patients: pathophysiology and therapeutic implications.Critical Care : the Official Journal of the Critical Care Forum 2023 November 21
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app