We have located links that may give you full text access.
JOURNAL ARTICLE
META-ANALYSIS
SYSTEMATIC REVIEW
Accuracy of the Montreal Cognitive Assessment tool for detecting mild cognitive impairment: A systematic review and meta-analysis.
INTRODUCTION: This systematic review evaluates the accuracy of the Montreal Cognitive Assessment (MoCA) for detecting mild cognitive impairment (MCI).
METHODS: We searched MEDLINE, PSYCInfo, EMBASE, and Cochrane CENTRAL (1995-2021) for studies comparing the MoCA with validated diagnostic criteria to identify MCI in general practice. Screening, data extraction, and risk of bias assessment were performed independently, in duplicate. Pooled sensitivity and specificity for MoCA cutoffs were estimated using bivariate meta-analysis.
RESULTS: Thirteen studies [2158 participants, 948(44%) with MCI] were included; 10 used Petersen criteria as the reference standard. Risk of bias of studies were high or unclear for all domains except reference standard. Sensitivity and specificity were 73.5%(95% confidence interval: 56.7-85.5) and 91.3%(84.6-95.3) at cutoff <23; 79.5%(67.1-88.0) and 83.7%(75.4-89.6) at cutoff <24; and 83.8%(75.6-89.6) and 70.8(62.1-78.3) at cutoff <25.
DISCUSSION: MoCA cutoffs <23 to <25 maximized the sum of sensitivity and specificity for detecting MCI. The risk of bias of included studies limits confidence in these findings.
METHODS: We searched MEDLINE, PSYCInfo, EMBASE, and Cochrane CENTRAL (1995-2021) for studies comparing the MoCA with validated diagnostic criteria to identify MCI in general practice. Screening, data extraction, and risk of bias assessment were performed independently, in duplicate. Pooled sensitivity and specificity for MoCA cutoffs were estimated using bivariate meta-analysis.
RESULTS: Thirteen studies [2158 participants, 948(44%) with MCI] were included; 10 used Petersen criteria as the reference standard. Risk of bias of studies were high or unclear for all domains except reference standard. Sensitivity and specificity were 73.5%(95% confidence interval: 56.7-85.5) and 91.3%(84.6-95.3) at cutoff <23; 79.5%(67.1-88.0) and 83.7%(75.4-89.6) at cutoff <24; and 83.8%(75.6-89.6) and 70.8(62.1-78.3) at cutoff <25.
DISCUSSION: MoCA cutoffs <23 to <25 maximized the sum of sensitivity and specificity for detecting MCI. The risk of bias of included studies limits confidence in these findings.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app