BACKGROUND: High-intensity stationary therapeutic ultrasound (HITU) technology is gaining popularity as an attractive modality for treating different conditions, but little is known about its application in aesthetics.
OBJECTIVE: To analyze the effects of stationary unfocused ultrasound (HITU technology) in treating localized fat in women's abdominal region.
METHODS: The sample consisted of 43 women with localized abdominal adiposity, assessed pre and post-treatment by assessment protocols, adversity analysis questionnaires, ultrasound exams, and serum level exams. The volunteers were randomly divided into three subgroups: G-1, who used the device off, G-2 received therapy with the device once a week for two months (Parameters: Pulsed - 100Hz - 50% - 4.0 W/cm2 - 20 minutes) and the G-3 who used the device on twice a week for a month (Parameters: Pulsed - 100Hz - 50% - 3.2W/cm2 - 30 minutes). All groups received eight sessions in total.
RESULTS: There was a significant reduction for G-3 in the plicometry of the lower right region ( p =0.01) in the comparison between the final and initial moments. In the comparison among the three research groups, there was a significant reduction in plicometry in the lower right ( p =0.03) and left ( p =0.02) regions in G3. Via ultrasound, a reduction in the fat layers average was observed in all groups. In G-3, there were significant differences in the left infraumbilical region ( p =0.02) and right ( p =0.04). In the group comparison, the right infraumbilical region showed significant differences ( p =0.04) for the G-3. No differences were found for weight, BMI, body fat percentage and supra, infra and umbilical perimetry ( p >0.05). The adverse reactions reported were: Mild hyperaemia (75%) and sensation of shock (21%), there were also reports of improvement in fluid retention in 93.7 percent of the volunteers, and most were satisfied with the result.
CONCLUSION: Both treatment protocols for the reduction of localized adiposity were effective compared to the placebo group, with a significant reduction in the use of ultrasound and plicometry in the concentration of fat in the lower abdominal region.
OBJECTIVE: To analyze the effects of stationary unfocused ultrasound (HITU technology) in treating localized fat in women's abdominal region.
METHODS: The sample consisted of 43 women with localized abdominal adiposity, assessed pre and post-treatment by assessment protocols, adversity analysis questionnaires, ultrasound exams, and serum level exams. The volunteers were randomly divided into three subgroups: G-1, who used the device off, G-2 received therapy with the device once a week for two months (Parameters: Pulsed - 100Hz - 50% - 4.0 W/cm2 - 20 minutes) and the G-3 who used the device on twice a week for a month (Parameters: Pulsed - 100Hz - 50% - 3.2W/cm2 - 30 minutes). All groups received eight sessions in total.
RESULTS: There was a significant reduction for G-3 in the plicometry of the lower right region ( p =0.01) in the comparison between the final and initial moments. In the comparison among the three research groups, there was a significant reduction in plicometry in the lower right ( p =0.03) and left ( p =0.02) regions in G3. Via ultrasound, a reduction in the fat layers average was observed in all groups. In G-3, there were significant differences in the left infraumbilical region ( p =0.02) and right ( p =0.04). In the group comparison, the right infraumbilical region showed significant differences ( p =0.04) for the G-3. No differences were found for weight, BMI, body fat percentage and supra, infra and umbilical perimetry ( p >0.05). The adverse reactions reported were: Mild hyperaemia (75%) and sensation of shock (21%), there were also reports of improvement in fluid retention in 93.7 percent of the volunteers, and most were satisfied with the result.
CONCLUSION: Both treatment protocols for the reduction of localized adiposity were effective compared to the placebo group, with a significant reduction in the use of ultrasound and plicometry in the concentration of fat in the lower abdominal region.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app