We have located links that may give you full text access.
Comparison of post contrast fluid attenuated inversion recovery, 3D T1-SPACE, and T1W MRI sequences with fat suppression in the diagnosis of infectious meningitis.
Neuroradiology Journal 2023 March 14
OBJECTIVE: To assess the usefulness of post contrast Fluid attenuated inversion recovery (FLAIR), 3D T1-SPACE, and T1W magnetic resonance imaging (MRI) sequences with fat suppression in diagnosis of infectious meningitis.
METHODS: 75 patients with clinical suspicion of meningitis were evaluated with post contrast FLAIR (PC-FLAIR), post contrast T1-SPACE (PC-T1-SPACE), and post contrast T1WI (PC-T1WI). Sensitivity, specificity, positive predictive value, and negative predictive value of individual sequences were assessed.
RESULTS: The sensitivity of PC-FLAIR (88.4%) was greater than PC-T1-SPACE (85.5%) and PC-T1WI (82.6%), considering cerebrospinal fluid (CSF) analysis as gold standard ( p < 0.05). Kappa inter-rater agreement between two radiologists was 0.921 for PC-T1-SPACE, 0.921 for PC-T1WI, and 1.0 for PC-FLAIR with a p value <0.05. Both PC-T1-SPACE and PC-FLAIR performed equally in sulcal space enhancement. PC-T1-SPACE and PC-T1WI performed better in evaluation of pachymeningeal enhancement, ependymal enhancement in cases of ventriculitis, whereas PC-FLAIR was more sensitive in assessment of basal cistern enhancement and enhancement along the cerebellar folia.
CONCLUSION: Meningeal enhancement could be better appreciated in PC-FLAIR image than PC-T1WI and PC-T1-SPACE. Enhancement in PC-T1-SPACE was comparable to that of PC-T1WI. Being a T1 based spin echo sequence, PC-T1-SPACE has all the advantages of PC-T1WI in addition to its ability to differentiate meningeal enhancement from leptomeningeal vessels. Hence, PC-T1WI can be replaced by PC-T1-SPACE and PC-FLAIR can be added to routine MRI protocol in suspected case of meningitis.
METHODS: 75 patients with clinical suspicion of meningitis were evaluated with post contrast FLAIR (PC-FLAIR), post contrast T1-SPACE (PC-T1-SPACE), and post contrast T1WI (PC-T1WI). Sensitivity, specificity, positive predictive value, and negative predictive value of individual sequences were assessed.
RESULTS: The sensitivity of PC-FLAIR (88.4%) was greater than PC-T1-SPACE (85.5%) and PC-T1WI (82.6%), considering cerebrospinal fluid (CSF) analysis as gold standard ( p < 0.05). Kappa inter-rater agreement between two radiologists was 0.921 for PC-T1-SPACE, 0.921 for PC-T1WI, and 1.0 for PC-FLAIR with a p value <0.05. Both PC-T1-SPACE and PC-FLAIR performed equally in sulcal space enhancement. PC-T1-SPACE and PC-T1WI performed better in evaluation of pachymeningeal enhancement, ependymal enhancement in cases of ventriculitis, whereas PC-FLAIR was more sensitive in assessment of basal cistern enhancement and enhancement along the cerebellar folia.
CONCLUSION: Meningeal enhancement could be better appreciated in PC-FLAIR image than PC-T1WI and PC-T1-SPACE. Enhancement in PC-T1-SPACE was comparable to that of PC-T1WI. Being a T1 based spin echo sequence, PC-T1-SPACE has all the advantages of PC-T1WI in addition to its ability to differentiate meningeal enhancement from leptomeningeal vessels. Hence, PC-T1WI can be replaced by PC-T1-SPACE and PC-FLAIR can be added to routine MRI protocol in suspected case of meningitis.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app