Intraoperative 3D imaging in plate osteosynthesis of proximal humerus fractures.
Archives of Orthopaedic and Trauma Surgery 2023 March 7
INTRODUCTION: Proximal humerus fractures are common and often associated with osteoporosis in the elderly. Unfortunately, the complication and revision rate for joint-preserving surgical treatment using locking plate osteosynthesis is still high. Problems include insufficient fracture reduction and implant misplacement. Using conventional intraoperative two dimensional (2D) X-ray imaging control in only two planes, a completely error-free assessment is not possible.
MATERIALS AND METHODS: The feasibility of intraoperative three-dimensional (3D) imaging control for locking plate osteosynthesis with screw tip cement augmentation of proximal humerus fractures was retrospectively studied in 14 cases with an isocentric mobile C-arm image intensifier set up parasagittal to the patients.
RESULTS: The intraoperative digital volume tomography (DVT) scans were feasible in all cases and showed excellent image quality. One patient showed inadequate fracture reduction in the imaging control, which then could be corrected. In another patient, a protruding head screw was detected, which could be replaced before augmentation. Cement distribution in the humeral head was consistent around the screw tips with no leakage into the joint.
CONCLUSION: This study shows that insufficient fracture reduction and implant misplacement can be easily and reliably detected by intraoperative DVT scan with an isocentric mobile C-arm set up in the usual parasagittal position to the patient.
MATERIALS AND METHODS: The feasibility of intraoperative three-dimensional (3D) imaging control for locking plate osteosynthesis with screw tip cement augmentation of proximal humerus fractures was retrospectively studied in 14 cases with an isocentric mobile C-arm image intensifier set up parasagittal to the patients.
RESULTS: The intraoperative digital volume tomography (DVT) scans were feasible in all cases and showed excellent image quality. One patient showed inadequate fracture reduction in the imaging control, which then could be corrected. In another patient, a protruding head screw was detected, which could be replaced before augmentation. Cement distribution in the humeral head was consistent around the screw tips with no leakage into the joint.
CONCLUSION: This study shows that insufficient fracture reduction and implant misplacement can be easily and reliably detected by intraoperative DVT scan with an isocentric mobile C-arm set up in the usual parasagittal position to the patient.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app