We have located links that may give you full text access.
Is it Possible to Avoid Liver Biopsy in Living Donors for Liver Transplantation by Using Two-Dimensional Shear Wave Elastography?
Transplantation Proceedings 2023 March 5
PURPOSE: The present study aims to evaluate the correlation of two-dimensional shear wave elastography results with histopathological findings performed simultaneously with liver biopsy (LB) in healthy liver transplant donors.
METHODS: A total of 53 living donors, 35 male and 18 female, were included in this prospective, observational, single-center study. Patients with abnormal liver function tests were not included in our study. Hepatosteatosis, fibrosis, and inflammation were evaluated with the Fatty Liver Inhibition of Progression and Steatosis, Activity, and Fibrosis algorithm of donor LB.
RESULTS: The mean age of the donors was 33.04 ± 9.07 years and the mean body mass index was 23.41 ± 6.23 kg/m2 . The mean elastography kilo pascal (kPA) value of all donors was determined as 6.03 ± 2.32 kPa. The mean LB activity scores of the donors were found to be 1.64 ± 1.18 and ranged from 0 to 5. There was no significant correlation between elastography kPa value and pathologic activity score, steatosis score, balloon degeneration, and inflammation grade fibrosis scores (P > .05).
CONCLUSION: Shear wave elastography measurements showed that the predictive power of pathologic findings in donor LB was not sufficient.
METHODS: A total of 53 living donors, 35 male and 18 female, were included in this prospective, observational, single-center study. Patients with abnormal liver function tests were not included in our study. Hepatosteatosis, fibrosis, and inflammation were evaluated with the Fatty Liver Inhibition of Progression and Steatosis, Activity, and Fibrosis algorithm of donor LB.
RESULTS: The mean age of the donors was 33.04 ± 9.07 years and the mean body mass index was 23.41 ± 6.23 kg/m2 . The mean elastography kilo pascal (kPA) value of all donors was determined as 6.03 ± 2.32 kPa. The mean LB activity scores of the donors were found to be 1.64 ± 1.18 and ranged from 0 to 5. There was no significant correlation between elastography kPa value and pathologic activity score, steatosis score, balloon degeneration, and inflammation grade fibrosis scores (P > .05).
CONCLUSION: Shear wave elastography measurements showed that the predictive power of pathologic findings in donor LB was not sufficient.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
The Effect of Albumin Administration in Critically Ill Patients: A Retrospective Single-Center Analysis.Critical Care Medicine 2024 Februrary 8
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app