Add like
Add dislike
Add to saved papers

Effect of 320-Row Computed Tomography Acquisition Technology on Coronary Computed Tomography Angiography-Derived Fractional Flow Reserve Based on Machine Learning: Systolic and Diastolic Scan Acquisition.

BACKGROUND: The aim of the study is to investigate the performance of coronary computed tomography angiography (CCTA)-derived fractional flow reserve (CT-FFR) in the same patient evaluated by different systolic and diastolic scans, aiming to explore whether 320-slice CT scanning acquisition protocol has an impact on CT-FFR value.

METHODS: One hundred forty-six patients with suspected coronary artery stenosis who underwent CCTA examination were included into the study. The prospective electrocardiogram gated trigger sequence scan was performed and electrocardiogram editors selected 2 optimal phases of systolic phase (preset collection trigger at 25% of R-R interval) and diastolic phase (preset collection trigger at 75% of R-R interval) for reconstruction. The lowest CT-FFR value (the CT-FFR value at the distal end of each vessel) and the lesion CT-FFR value (at 2 cm distal to the stenosis) after coronary artery stenosis were calculated for each vessel. The difference of CT-FFR values between the 2 scanning techniques was compared using paired Wilcoxon signed-rank test. Pearson correlation value and Bland-Altman were performed to evaluate the consistency of CT-FFR values.

RESULTS: A total of 366 coronary arteries from the remaining 122 patients were analyzed. There was no significant difference regarding the lowest CT-FFR values between systole phase and diastole phase across all vessels. In addition, there was no significant difference in the lesion CT-FFR value after coronary artery stenosis between systole phase and diastole phase across all vessels. The CT-FFR value between the 2 reconstruction techniques had excellent correlation and minimal bias in all groups. The correlation coefficient of the lesion CT-FFR values for left anterior descending branch, left circumflex branch, and right coronary artery were 0.86, 0.84, and 0.76, respectively.

CONCLUSIONS: Coronary computed tomography angiography-derived fractional flow reserve based on artificial intelligence deep learning neural network has stable performance, is not affected by the acquisition phase technology of 320-slice CT scan, and has high consistency with the evaluation of hemodynamics after coronary artery stenosis.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app