First-Pass Effect in M1-Occlusion Stroke Patients Treated with Combined Stent-Retriever/Large-Bore Distal Aspiration Catheter Thrombectomy.

INTRODUCTION: Combined stent-retriever/large-bore distal aspiration catheter (LB-DAC) thrombectomy was recently introduced to treat large-vessel occlusion; however, it is unclear whether larger inner diameters improve outcomes. We compared angiographic and clinical outcomes in patients with occlusions of the M1 segment of the middle cerebral artery treated with mechanical thrombectomy using extra-LB-DAC versus LB-DAC in combination with stent-retrievers.

METHODS: We analyzed consecutive patients with M1 occlusion included in the ROSSETTI registry treated with non-balloon guide catheter combined LB-DAC/stent-retriever thrombectomy between June 2019 and April 2022. We compared demographics, baseline clinical variables, procedural variables, angiographic outcomes, and clinical outcomes [National Institute of Health Stroke Scale score at 24 h (24h-NIHSS) and modified Rankin scale score at 3 months] between patients treated with extra-LB-DAC (Sofia Plus, MIVI Q6, Catalyst7; inner diameter, 0.068″-0.070″) versus LB-DAC (Sofia 5F, MIVI Q5, Catalyst 6; inner diameter, 0.055″-0.064″). Primary outcome was the first-pass effect (FPE) rate, defined as near-complete/complete reperfusion (mTICI 2c-3) after a single pass of the device.

RESULTS: We included 324 patients (extra-LB-DAC, 185, 57.1% patients). Demographics, clinical data, and clinical outcomes were similar between the two groups; however, there was a trend towards improvement in National Institute of Health Stroke Scale score at 24 h (24h-NIHSS) in the cohort treated with extra-LB-DAC 9 points (IQR 4;16 points) vs. 12 points (IQR 4;18 points, P = 0.083). Patients treated with extra-LB-DAC had higher FPE rate (47% vs. 30.9%; P = 0.003) and higher modified FPE (mTICI ≥ 2b after a single pass) rate (65.9% vs 46.8%; P = 0.001). The use of extra-LB-DAC was an independent factor in predicting FPE (odds ratio 1.982, 95% confidence interval 1.250-3.143, P = 0.004).

CONCLUSION: Our results suggest that in combined LB-DAC/stent-retriever thrombectomy, a larger aspiration catheter inner diameter is associated with higher rates of FPE and mFPE.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app